ATS48C41Q Schneider soft starter heavy-duty 220KW motor application 410 rated current three-phase 380V
- Name: ATS48C41Q Schneider soft starter heavy-duty 220KW motor application 410 rated current three-phase 380V
- Brand: Schneider
- Model: ATS48C41Q
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
range of product | Altistart 48 |
---|---|
product or component type | Soft starter |
product destination | Asynchronous motors |
product specific application | Heavy duty industry and pumps |
device short name | ATS48 |
utilisation category | AC-53A |
Ue power supply voltage | 230…415 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % |
motor power kW | 90 kW at 230 V connection in the motor supply line for severe applications 110 kW at 230 V connection in the motor supply line for standard applications 160 kW at 230 V connection to the motor delta terminals for severe applications 160 kW at 400 V connection in the motor supply line for severe applications 220 kW at 230 V connection to the motor delta terminals for standard applications 220 kW at 400 V connection in the motor supply line for standard applications 250 kW at 400 V connection to the motor delta terminals for severe applications 315 kW at 400 V connection to the motor delta terminals for standard applications |
device connection | In the motor supply line To the motor delta terminals |
protection type | Phase failure: line Thermal protection: motor Thermal protection: starter |
Standards | EN/IEC 60947-4-2 |
product certifications | DNV C-Tick CSA NOM 117 TCF UL SEPRO GOST CCC |
Marking | CE |
discrete input number | 5 |
discrete input type | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm |
discrete input logic | Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
minimum switching current | 10 mA at 6 V DC for relay outputs |
discrete output number | 2 |
discrete output type | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
analogue output type | Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm |
communication port protocol | Modbus |
connector type | 1 RJ45 |
communication data link | Serial |
physical interface | RS485 multidrop |
transmission rate | 4800, 9600 or 19200 bps |
function available | External bypass (optional) |
operating position | Vertical +/- 10 degree |
Height | 670 mm |
width | 400 mm |
Depth | 300 mm |
Net weight | 51.4 kg |
electromagnetic compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
relative humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
ambient air temperature for operation | 40…60 °C (with current derating of 2 % per °C) -10…40 °C (without derating) |
Ambient air temperature for storage | -25…70 °C |
operating altitude | <= 1000 m without derating > 1000…2000 m with current derating of 2.2 % per additional 100 m |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 39 cm |
Package 1 Width | 58 cm |
Package 1 Length | 78.5 cm |
Package 1 Weight | 54.5 kg |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 1 |
Package 2 Height | 75 cm |
Package 2 Width | 60 cm |
Package 2 Length | 80 cm |
Package 2 Weight | 63 kg |
Warranty | 18 months |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”