LC1D205M7C Schneider LC1D three-level AC contactor AC24 220V 380V.
- Name: LC1D205M7C Schneider LC1D three-level AC contactor AC24 220V 380V.
- Brand: Schneider
- Model: LC1D205M7C
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER LC1D three-level AC contactor LC1D205M7C AC24 220V 380V.
Product Series of LC1D205M7C | TeSys Deca |
---|---|
Product Series | TeSys Deca |
product type | Contactor |
product short name | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC- 3AC-1 |
number of poles | 3P |
Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz Power circuit: <= 460 V DC |
Rated operating current [Ie] | 275 A 40 °C) at <= 440 V AC AC-1 for power circuits 205 A 40 °C) at <= 440 V AC AC-3 for power circuits |
[Uc] control circuit voltage | 230V AC 50/60Hz |
Motor power (kW) | 100 kW at 1000 V AC 50/60 Hz (AC-3) 63 kW at 220/240 V AC 50/60 Hz (AC-3) 110 kW at 380/400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660/690 V AC 50/60 Hz (AC-3) |
model of LC1D205M7C | LC1D |
Loop contact type | 3 NO |
protection cap | None |
Conventional thermal current [Ith] | 275 A at <40 °C for power circuits |
Rated short-time withstand current [Icw] | 1500 A at <40 °C – 10 s for power circuit 920 A at <40 °C – 30 s for power circuit 740 A at <40 °C – 1 min for power circuit 500 A at <40 °C – 3 minutes for power circuit 400 A at <40 °C – 10 minutes for power circuit |
Fuses for use with relays | 200 A aM at <= 440 V for power circuits 315 A gG at <= 440 V for power circuits |
average impedance | 0.33 mΩ – Ith 275 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 1000 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
pollution level | 3 |
Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 |
Mechanical life | 8 Mcycles |
Electrical life | 0.55 Mcycles 275 A AC-1 Ue <= 440 V 1.1 Mcycles 170 A AC-3 Ue <= 440 V 1 Mcycles 118 A AC-3 Ue 660/690 V |
Control loop characteristics | AC at 50/60 Hz |
Control voltage limit | 0.35…0.55 Uc -5…55 °C release 50/60 Hz 0.85…1.15 Uc -5…55 °C run 50/60 Hz |
(~50Hz pickup) power consumption (VA) | 805 VA 50 Hz 0.3 20 °C) 970 VA 60 Hz 0.3 20 °C) |
(~50Hz hold) power consumption (VA) | 55 VA 50 Hz 0.3 20 °C) 66 VA 60 Hz 0.3 20 °C) |
heat dissipation | 18…24W |
action time | 20…35 ms close 130 ms break |
operating frequency | 2400 cycles/h at <55 °C |
Wiring capacity | Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power circuit: Cable with lugs Cable selection: single-strand hard wire without wire terminal |
Tightening torque | Power circuit: 18 Nm Via busbar terminals Power circuit: 18 Nm Via cable connector Control circuit: 1.2 Nm Via bolt fastening |
Auxiliary contact type | Does not contain |
installation method | Chassis mounting rail installation |
standard | GB 14048.4 IEC 60947-4-1 |
certified product | CCC CE |
IP protection class | IP20 front panel with LA9F conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27 |
high of LC1D205M7C | 174 mm |
width of LC1D205M7C | 168.5 mm |
depth of LC1D205M7C | 181 mm |
Product Weight | 5.2kg |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”