PRODUCT INFORMATION OF SCHNEIDER LC1D three-level AC contactor LC1D245M7C AC24 220V 380V.
range | TeSys |
---|---|
range of product | TeSys F |
product or component type | Contactor |
device short name | LC1F |
contactor application | Motor control Resistive load |
utilisation category | AC-4 AC-1 AC-3 |
poles description | 3P |
[Ue] rated operational voltage | <= 1000 V AC-1 <= 690 V AC-3 <= 690 V AC-4 <= 460 V DC |
[Uc] control circuit voltage | 220 V AC 40…400 Hz |
[Ie] rated operational current | 350 A (at <40 °C) at <= 440 V AC AC-1 265 A (at <55 °C) at <= 440 V AC AC-3 |
[Uimp] rated impulse withstand voltage | 8 kV |
[Ith] conventional free air thermal current | 350 A (at 40 °C) |
rated breaking capacity | 2120 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 2200 A 40 °C – 10 s 1230 A 40 °C – 30 s 950 A 40 °C – 1 min 620 A 40 °C – 3 min 480 A 40 °C – 10 min |
associated fuse rating | 315 A aM at <= 440 V 400 A gG at <= 440 V |
average impedance | 0.3 mOhm – Ith 350 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
power dissipation per pole | 37 W AC-1 21 W AC-3 |
overvoltage category | III |
power pole contact composition | 3 NO |
motor power kW | 132 kW at 380…400 V AC 50/60 Hz (AC-3) 140 kW at 415 V AC 50/60 Hz (AC-3) 140 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660…690 V AC 50/60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 220…230 V AC 50/60 Hz (AC-3) 51 kW at 400 V AC 50/60 Hz (AC-4) |
control circuit voltage limits | Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C) Drop-out: 0.15…0.2 Uc 40…400 Hz (at 55 °C) |
mechanical durability | 10 Mcycles |
inrush power in VA | 650 VA, 40…400 Hz cos phi 0.9 (at 20 °C) |
hold-in power consumption in VA | 10 VA, 40…400 Hz cos phi 0.9 (at 20 °C) |
maximum operating rate | 2400 cyc/h 55 °C |
operating time | 40…65 ms closing 100…170 ms opening |
connections – terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) – busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: connector 1 cable(s) 240 mm² Power circuit: bolted connection |
tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
mounting support | Plate |
heat dissipation | 8 W |
motor power range | 55…100 kW at 200…240 V 3 phases 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases |
motor starter type | Direct on-line contactor |
contactor coil voltage | 220 V AC standard |
Standards | JIS C8201-4-1 IEC 60947-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1 |
product certifications | RINA RMRoS CSA CB UL BV ABS LROS (Lloyds register of shipping) DNV UKCA |
compatibility code | LC1F |
control circuit type | AC at 40…400 Hz |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
permissible ambient air temperature around the device | -40…70 °C |
Height of LC1D245M7C | 203 mm |
width of LC1D245M7C | 201.5 mm |
Depth of LC1D245M7C | 213 mm |
operating altitude | 3000 m without derating |
Net weight of LC1D245M7C | 7.44 kg |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”