Schneider ATV12H075M3 inverter ATV12 series 0.75KW 220V spot.

Schneider ATV12H075M3 inverter ATV12 series 0.75KW 220V spot.

Share to:

Aditional Informations

PRODUCT INFORMATION OF SCHNEIDER Schneider ATV12H075M3 inverter ATV12 series ATV12H075M3 0.75KW 220V spot.

Main || Schneider ATV12H075M3

Range of product Altivar 12
Product or component type Variable speed drive
Product specific application Simple machine
Mounting mode Cabinet mount
Communication port protocol Modbus
supply frequency 50/60 Hz +/- 5 %
[Us] rated supply voltage 200…240 V – 15…10 %
Nominal output current 4.2 A
motor power hp 1 hp
motor power kW 0.75 kW
motor power hp 1 hp
EMC filter of Schneider ATV12H075M3 inverter Without EMC filter
IP degree of protection IP20
Discrete input number 4
Discrete output number 2
Analogue input number 1
Analogue output number 1
Relay output number 1
Physical interface 2-wire RS 485
Connector type 1 RJ45
continuous output current 4.2 A at 4 kHz
method of access Server Modbus serial
Speed drive output frequency 0.5…400 Hz
speed range of Schneider ATV12H075M3 inverter 1…20
sampling duration 20 ms, tolerance +/- 1 ms for logic input
10 ms for analogue input
linearity error +/- 0.3 % of maximum value for analogue input
frequency resolution Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
time constant 20 ms +/- 1 ms for reference change
Transmission rate 9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frame RTU
Number of addresses 1…247
Data format of Schneider ATV12H075M3 inverter 8 bits, configurable odd, even or no parity
communication service Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
Type of polarization No impedance
4 quadrant operation possible False
Asynchronous motor control profile Sensorless flux vector control
Voltage/frequency ratio (V/f)
Quadratic voltage/frequency ratio
Maximum output frequency 4 kHz
transient overtorque 150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration ramps Linear from 0 to 999.9 s
S
U
Motor slip compensation Preset in factory
Adjustable
switching frequency 2…16 kHz adjustable
4…16 kHz with derating factor
Nominal switching frequency 4 kHz
Braking to standstill By DC injection
Brake chopper integrated False
line current of Schneider ATV12H075M3 inverter 6.3 A at 100 V (heavy duty)
5.3 A at 120 V (heavy duty)
Maximum input current 5.3 A
Maximum output voltage 240 V
apparent power 2.2 kVA at 240 V (heavy duty)
maximum transient current 6.3 A during 60 s (heavy duty)
6.9 A during 2 s (heavy duty)
Network frequency 50…60 Hz
Relative symmetric network frequency tolerance 5 %
Prospective line Isc 5 kA
Base load current at high overload 4.2 A
power dissipation in W Natural: 41.0 W
With safety function Safely Limited Speed (SLS) False
With safety function Safe brake management (SBC/SBT) False
With safety function Safe Operating Stop (SOS) False
With safety function Safe Position (SP) False
With safety function Safe programmable logic False
With safety function Safe Speed Monitor (SSM) False
With safety function Safe Stop 1 (SS1) False
With sft fct Safe Stop 2 (SS2) False
With safety function Safe torque off (STO) False
With safety function Safely Limited Position (SLP) False
With safety function Safe Direction (SDI) False
protection type Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
Tightening torque 0.8 N.m
Insulation Electrical between power and control
Quantity per set Set of 1
Width of Schneider ATV12H075M3 inverter 72 mm
Height of Schneider ATV12H075M3 inverter 143 mm
Depth of Schneider ATV12H075M3 inverter 131.2 mm
Product weight 0.8 kg
operating altitude <= 1000 m without derating
> 1000…3000 m with current derating 1 % per 100 m
Operating position Vertical +/- 10 degree
Product certifications NOM
CSA
C-Tick
UL
GOST
RCM
KC
Marking of Schneider ATV12H075M3 inverter CE
Standards of Schneider ATV12H075M3 inverter UL 508C
UL 618000-5-1
EN/IEC 61800-5-1
EN/IEC 61800-3
Assembly style of Schneider ATV12H075M3 inverter With heat sink
electromagnetic compatibility Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Surge immunity test level 3 conforming to EN/IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13…200 Hz
Maximum deflection under vibratory load (during operation) 1.5 mm at 2…13 Hz
Overvoltage category Class III
Regulation loop Adjustable PID regulator
electromagnetic emission Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m
Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4…12 kHz shielded motor cable <20 m
vibration resistance 1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f = 3…13 Hz) – drive unmounted on symmetrical DIN rail – conforming to EN/IEC 60068-2-6
shock resistance of Schneider ATV12H075M3 inverter 15 gn conforming to EN/IEC 60068-2-27 for 11 ms
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Noise level of Schneider ATV12H075M3 inverter 0 dB
Pollution degree of Schneider ATV12H075M3 inverter 2
Ambient air transport temperature -25…70 °C
ambient air temperature for operation -10…40 °C without derating
40…60 °C with current derating 2.2 % per °C
Ambient air temperature for storage -25…70 °C

 

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us