Schneider phase sequence lack of phase protector RM22TG20 relay two or three phase control phase lack of protector

Schneider phase sequence lack of phase protector RM22TG20 relay two or three phase control phase lack of protector

Share to:

Aditional Informations

PRODUCT INFORMATION OF SCHNEIDER phase sequence lack of phase protector RM22TG20 relay two or three phase control phase lack of protector

 

main information

Product Series Harmony Control Relays
product type 3-phase control relay
relay type Control relay
Number of grid phases Phase 3
Relay name RM22TG
Relay Monitoring Parameters Phase order
Phase failure detection (2 or more phase cut)
delay type None
Switching capacity in VA 2000VA
Measuring range 183…528 V voltage AC
contact type 2 OC
reset time 1500 ms at maximum voltage
Maximum Switching Voltage 250V AC
Minimum switching current [Imin] 10 mA at 5 V DC
Maximum switching current 8A AC
Rated supply voltage [Us] 208…480 V AC
Power supply voltage range 183…528 V AC
operating limits 183…528V AC
Power consumption VA 15 VA at 480 V AC 60 Hz
Voltage Monitoring Threshold < 100 V AC
supply voltage frequency 50…60 Hz +/- 10 %
output contact 2 C/O
Rising delay at power-up 650ms
Response time <= 200 ms
Type of overvoltage III according to IEC 60664-1
III according to UL 508
Insulation resistance > 100 MΩ at 500 V DC conforming to IEC 60255-27
installation location Any position
Wiring capacity Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) Solid without wire terminal
Screw terminal, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16 ) flexible wire with wire terminal
screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) rigid wire without wire terminal
screw terminal, 1 x 0.2…1 x 2.5 mm² ( AWG 24…AWG 14) flexible wire with wire terminal
Tightening torque 0.6…1 Nm conforming to IEC 60947-1
covering material Flame retardant plastic
LED status LED (yellow) relay ON
LED (green) energized
installation method 35 mm DIN rail conforming to EN/IEC 60715
Electrical life 100000 times
Mechanical life 10000000 times
use category AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
Safe and reliable data MTTFd = 924.6 years
B10d = 850000
contact material Cadmium free
width of Schneider phase sequence lack 22.5 mm
Product Weight 0.09 kg
Anti-instantaneous power failure 10ms
electromagnetic compatibility Exemption for use in residential, commercial and light-industrial environments Transmission standards per EN/IEC 61000-6-1
Exemption for industrial environments per EN/IEC 61000-6-2 Transmission standards for residential, commercial and light-
industrial environments per EN/IEC 61000- 6-3
Transmission standards for industrial environments in accordance with EN/IEC 61000-6-4
Anti-static interference – test level: 6 kV (contact discharge) Level 3 in accordance with IEC 61000-4-2
Anti-static interference – test level: 8 kV (air Discharge) Class 3 Complies with IEC 61000-4-2
Radio Frequency Electromagnetic Field Radiation Immunity Test – Test Level: 10 V/m3 Class Complies with IEC 61000-4-3 Immunity
to Fast Transients – Test Level: 4 kV (Direct Connection) Class 4 Complies with IEC 61000-4-4
Immunity to fast transients – Test level: 2 kV (capacitive coupling) level 4 Complies with IEC 61000-4-4
Surge discharge immunity – Test level: 4 kV (Common mode) level 4 Conforms to IEC 61000 -4-5
Surge Discharge Immunity- Test Level: 2 kV (Differential Mode) Level 4 Conforms to IEC 61000-4-5
Conducted and Radiated Emissions Group B 1 Conforms to CISPR 11
Conducted and Radiated Emissions Class B Conforms to CISPR 22
Standards compliant EN/IEC 60255-1
certified product CE
EAC
RCM
GL
CSA
UL
CCC
storage environment temperature -40…70°C
ambient temperature -20…50 °C at 60 Hz
-20…60 °C at 50 Hz AC/DC
Relative humidity 93…97 % at 25…55 °C conforming to IEC 60068-2-30
Anti-vibration of Schneider phase sequence lack 0.075 mm (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) during operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) conforming to IEC 60068-2-6 during operation
impact resistance 15 gn (duration = 11 ms) for non-operating according to IEC 60068-2-27
5 gn (duration = 11 ms) for operating according to IEC 60068-2-27
IP protection class IP20 according to IEC 60529 (screw terminals)
IP40 according to IEC 60529 (housing)
IP50 according to IEC 60529 (front panel)
pollution level 3 according to IEC 60664-1
3 according to UL 508
Dielectric test winding and winding, winding voltage to ground 2.5 kV AC 50 Hz, 1 minute conforming to IEC 60255-27
Warranty of Schneider phase sequence lack 18 months

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us