150-F135NBRD Rockwell AB SMC Flex soft start current 135A.

150-F135NBRD Rockwell AB SMC Flex soft start current 135A.

Share to:

Aditional Informations

PRODUCT INFORMATION OF 150-F135NBRD Rockwell AB SMC Flex soft start current 135A.

With display Yes
Voltage type for actuating AC/DC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 24 V
Rated control supply voltage at AC 60 Hz 24 V
Overload current for line connected devices 34 A
Overload current for delta connected devices 59 A
Controller type Soft starter
Control options Brake control
Trip classes 10, 15, 20 and 30
Trip current rating 117% of motor FLC
Transformer control module 75VA @ 100…240V AC (-15%, +10%)
Heatsink fan rating 20VA @ 110/120V AC or 220/240V AC
DV/DT protection RC snubber network for power circuit
Repetitive peak inverse voltage rating 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz for power circuit
Line connected motor power, max 90 kW @ 500V AC, 50 Hz, 3-phase
Delta connected motor power, max 75 kW @ 230V AC, 50 Hz, 3-phase
Rated impulse voltage 6000V per IEC for power circuit
Dielectric withstand 2500V per IEC for power circuit
Line connected motor current 34…135 A @ 600/Y/690V AC, 3-phase
Delta connected motor current 59…234 A @ 500/575V AC, 3-phase
Ampere tested european style, max 6,9 gRB 73xxx400 6,6URD33xxx500 @ 690V for maximum FLC
Ampere tested north american style, max A070URD33xxx500 @ 690V for maximum FLC
Transient protection Metal oxide varistors: 220 Joules (optional) for power circuit
Insulation voltage Rated 500V per IEC for power circuit
Rated operational voltage 200…480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device list Standard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts 1 for auxiliary contacts
High capacity available fault current, max 70 kA @ 600V, maximum current 400 A time delay Class J or Class L fuse for inside delta connected motors
Type of current AC for auxiliary contacts
Conventional thermal current (Ith) AC/DC: 5 A for auxiliary contacts
Type of control circuit Electromagnetic relay for auxiliary contacts
Type of contacts Programmable NO/NC for auxiliary contacts
Utilization category MG 1 per UL/CSA/NEMA for power circuit
Standard controller feature Status indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max 70 kA @ 690V for maximum FLC
Optional controller feature SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0…400% of the motor’s full-load current rating
Rated control supply voltage at DC 24 V
Integrated motor overload protection Yes
Short circuit protection device performance (SCPD) type Type 1
Number of sensors, max 6 for PTC input ratings
Inrush current control module 5 A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max 30V for PTC input ratings
Transient watts control module 60 W @ 24V DC (-15%, +10%)
Steady state watts control module 24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max <7.5 for PTC input ratings
Response time 800 ms for PTC input ratings
Inrush time control module 250 ms @ 24V DC (-15%, +10%)
Transient time control module 500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max 1500 Ohm for PTC input ratings
Tachometer input 0…5V DC, 4.5V DC = 100% Speed
Allen bradley power supply control module, min 1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance 25 Ohm ± 10 Ohm for PTC input ratings
Response resistance 3400 Ohm ± 150 Ohm for PTC input ratings
Reset resistance 1600 Ohm ± 100 Ohm for PTC input ratings
Input OFF-state voltage, max 50V AC, 10V DC/12V AC for control circuit
Input ON-state voltage, min 85V AC, 19.2V DC/20.4V AC for control circuit
Rated operational current 3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts
Input ON-state current 20 mA @ 120V AC/40mA @ 240V AC, 7.6 mA @ 24V AC/DC for control circuit
Contact type auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us