150-F25NBDB Rockwell AB SMC Flex soft starter current 25A.

150-F25NBDB Rockwell AB SMC Flex soft starter current 25A.

Share to:

Aditional Informations

PRODUCT INFORMATION OF 150-F25NBDB Rockwell AB SMC Flex soft starter current 25A.

With display Yes
Voltage type for actuating AC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 100 V
Rated control supply voltage at AC 60 Hz 100 V
Overload current for line connected devices 5 A
Overload current for delta connected devices 8.6 A
Controller type Soft starter
Control options Pump control
Trip classes 10, 15, 20 and 30
Trip current rating 117% of motor FLC
Transformer control module 75VA @ 100…240V AC (-15%, +10%)
Heatsink fan rating 20VA @ 110/120V AC or 220/240V AC
DV/DT protection RC snubber network for power circuit
Repetitive peak inverse voltage rating 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz for power circuit
Line connected motor power, max 7.5 Hp @ 230V AC, 60 Hz, 3-phase
Delta connected motor power, max 40 Hp @ 575V AC, 60 Hz, 3-phase
Rated impulse voltage 6000V per IEC for power circuit
Dielectric withstand 2500V per IEC for power circuit
Line connected motor current 5…25 A @ 500/575V AC, 3-phase
Delta connected motor current 8.7…43 A @ 500/575V AC, 3-phase
Transient protection Metal oxide varistors: 220 Joules (optional) for power circuit
Insulation voltage Rated 500V per IEC for power circuit
Rated operational voltage 200…480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device list Standard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts 1 for auxiliary contacts
High capacity available fault current, max 70 kA @ 600V, maximum current 90 A time delay Class J or Class L fuse for inside delta connected motors
Type of current AC for auxiliary contacts
Conventional thermal current (Ith) AC/DC: 5 A for auxiliary contacts
Type of control circuit Electromagnetic relay for auxiliary contacts
Type of contacts Programmable NO/NC for auxiliary contacts
Utilization category MG 1 per UL/CSA/NEMA for power circuit
Standard controller feature Status indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max 5 kA @ 200…600V, maximum standard fuse 150 A for delta device operational current rating
Optional controller feature SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0…400% of the motor’s full-load current rating
Integrated motor overload protection Yes
Short circuit protection device performance (SCPD) type Type 1
Number of sensors, max 6 for PTC input ratings
Inrush current control module 5 A @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = open), max 30V for PTC input ratings
Transient watts control module 60 W @ 24V DC (-15%, +10%)
Steady state watts control module 24 W @ 24V DC (-15%, +10%)
Voltage at PTC terminals (RPTC = 4 kΩ), max <7.5 for PTC input ratings
Response time 800 ms for PTC input ratings
Inrush time control module 250 ms @ 24V DC (-15%, +10%)
Transient time control module 500 ms @ 24V DC (-15%, +10%)
Cold resistance of PTC sensor chain, max 1500 Ohm for PTC input ratings
Tachometer input 0…5V DC, 4.5V DC = 100% Speed
Allen bradley power supply control module, min 1606-XLP50E @ 24V DC (-15%, +10%)
Short circuit trip resistance 25 Ohm ± 10 Ohm for PTC input ratings
Response resistance 3400 Ohm ± 150 Ohm for PTC input ratings
Reset resistance 1600 Ohm ± 100 Ohm for PTC input ratings
Input OFF-state voltage, max 50V AC, 10V DC/12V AC for control circuit
Input ON-state voltage, min 85V AC, 19.2V DC/20.4V AC for control circuit
Lower line side cable size 0.8…2.5 mm2 (18…14 AWG) for power terminals
Lower load side cable size 0.8…2.5 mm2 (18…14 AWG) for power terminals
Upper load side cable size 2.5…50 mm2 (14…1 AWG) for load power terminals
Upper line side cable size 2.5…95 mm2 (14…3/0 AWG) for line power terminals
Rated operational current 3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts
Input ON-state current 20 mA @ 120V AC/40mA @ 240V AC, 7.6 mA @ 24V AC/DC for control circuit
Contact type auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us