range of product | Altivar 312 |
---|---|
product or component type | Variable speed drive |
product destination | Asynchronous motors |
product specific application | Simple machine |
assembly style | With heat sink |
component name | ATV312 |
motor power kW | 0.75 kW |
motor power hp | 1 hp |
[Us] rated supply voltage | 380…500 V – 15…10 % |
supply frequency | 50…60 Hz – 5…5 % |
network number of phases | 3 phases |
line current | 3.6 A at 380 V, Isc = 5 kA 2.7 A at 500 V |
EMC filter | Integrated |
apparent power | 2.4 kVA |
maximum transient current | 3.5 A for 60 s |
power dissipation in W | 41 W at nominal load |
speed range | 1…50 |
asynchronous motor control profile | Sensorless flux vector control with PWM type motor control signal Factory set : constant torque |
electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 terminal 2.5 mm² AWG 14 L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 5 mm² AWG 10 |
supply of ATV312H075N4 inverter | Internal supply for logic inputs: 19…30 V 100 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (2.2 to 10 kOhm): 10…10.8 V 10 mA, protection type: overload and short-circuit protection |
communication port protocol | CANopen Modbus |
IP degree of protection | IP20 on upper part without cover plate IP21 on connection terminals IP31 on upper part IP41 on upper part |
option card | Communication card for CANopen daisy chain Communication card for DeviceNet Communication card for Fipio Communication card for Modbus TCP Communication card for Profibus DP |
supply voltage limits | 323…550 V |
prospective line Isc | 5 kA |
continuous output current | 2.3 A at 4 kHz |
Output frequency | 0…500 Hz |
nominal switching frequency | 4 kHz |
switching frequency | 2…16 kHz adjustable |
transient overtorque | 170…200 % of nominal motor torque |
braking torque | 150 % during 60 s with braking resistor 100 % with braking resistor continuously 150 % without braking resistor |
regulation loop | Frequency PI regulator |
motor slip compensation | Adjustable Automatic whatever the load Suppressable |
output voltage | <= power supply voltage |
tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6: 0.6 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 1.2 N.m |
insulation | Electrical between power and control |
analogue input number | 3 |
analogue input type | AI1 configurable voltage 0…10 V, input voltage 30 V max, impedance: 30000 Ohm AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm AI3 configurable current 0…20 mA, impedance: 250 Ohm |
sampling duration | AI1, AI2, AI3: 8 ms analog LI1…LI6: 4 ms discrete |
response time | AOV, AOC 8 ms for analog R1A, R1B, R1C, R2A, R2B 8 ms for discrete |
linearity error | +/- 0.2 % for output |
analogue output number | 1 |
analogue output type | AOC configurable current: 0…20 mA, impedance: 800 Ohm, resolution: 8 bits AOV configurable voltage: 0…10 V, impedance: 470 Ohm, resolution: 8 bits |
discrete input logic | Logic input not wired (LI1…LI4), < 13 V (state 1) Negative logic (source) (LI1…LI6), > 19 V (state 0) Positive logic (source) (LI1…LI6), < 5 V (state 0), > 11 V (state 1) |
discrete output number | 2 |
discrete output type | Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC – 100000 cycles Configurable relay logic: (R2A, R2B) NC – 100000 cycles |
minimum switching current | R1-R2 10 mA at 5 V DC |
maximum switching current | R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms |
discrete input number | 6 |
discrete input type | (LI1…LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm |
acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.1 to 999.9 s |
braking to standstill | By DC injection |
protection type | Input phase breaks: drive Line supply overvoltage and undervoltage safety circuits: drive Line supply phase loss safety function, for three phases supply: drive Motor phase breaks: drive Overcurrent between output phases and earth (on power up only): drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: motor |
insulation resistance | >= 500 mOhm 500 V DC for 1 minute |
local signalling | 1 LED (red) for drive voltage Four 7-segment display units for CANopen bus status |
time constant | 5 ms for reference change |
frequency resolution | Analog input: 0.1…100 Hz Display unit: 0.1 Hz |
connector type | 1 RJ45 for Modbus/CANopen |
physical interface | RS485 multidrop serial link |
transmission frame | RTU |
transmission rate | 10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen 4800, 9600 or 19200 bps for Modbus |
number of addresses | 1…127 for CANopen 1…247 for Modbus |
number of drive | 127 for CANopen 31 for Modbus |
Marking of ATV312H075N4 inverter | CE |
operating position | Vertical +/- 10 degree |
Height of ATV312H075N4 inverter | 143 mm |
width of ATV312H075N4 inverter | 107 mm |
Depth of ATV312H075N4 inverter | 152 mm |
Net weight | 1.8 kg |
dielectric strength | 2410 V DC between earth and power terminals 3400 V AC between control and power terminals |
electromagnetic compatibility | 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Standards of ATV312H075N4 inverter | IEC 61800-3 IEC 61800-5-1 |
product certifications | NOM C-Tick CSA UL DNV GOST |
pollution degree | 2 |
protective treatment | TC |
vibration resistance | 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Ambient air temperature for storage | -25…70 °C |
ambient air temperature for operation | -10…50 °C without derating (with protective cover on top of the drive) -10…60 °C with derating factor (without protective cover on top of the drive) |
operating altitude | <= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 17.079 cm |
Package 1 Width | 17.183 cm |
Package 1 Length | 20.748 cm |
Package 1 Weight | 1.941 kg |
Unit Type of Package 2 | S06 |
Number of Units in Package 2 | 27 |
Package 2 Height | 73.5 cm |
Package 2 Width | 60.0 cm |
Package 2 Length | 80.0 cm |
Package 2 Weight | 63.0 kg |
Warranty | 18 months |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”