ATV61HD55N4 original Schneider inverter 55KW 380V ATV61 series spot supply
- Name: ATV61HD55N4 original Schneider inverter 55KW 380V ATV61 series spot supply
- Brand: Schneider
- Model: ATV61HD55N4
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER ATV61HD55N4 original Schneider inverter 55KW 380V ATV61 series spot supply
range of product | Altivar 61 |
---|---|
product or component type | Variable speed drive |
product specific application | Pumping and ventilation machine |
component name | ATV61 |
motor power kW | 55 kW, 3 phases at 380…480 V |
motor power hp | 75 hp, 3 phases at 380…480 V |
power supply voltage | 380…480 V – 15…10 % |
supply number of phases | 3 phases |
line current | 101 A for 480 V 3 phases 55 kW / 75 hp 120 A for 380 V 3 phases 55 kW / 75 hp |
EMC filter of ATV61HD55N4 original Schneider inverter | Level 3 EMC filter |
assembly style | With heat sink |
apparent power | 79 kVA at 380 V 3 phases 55 kW / 75 hp |
maximum prospective line Isc | 22 kA for 3 phases |
maximum transient current | 139.2 A for 60 s, 3 phases |
nominal switching frequency | 12 kHz |
switching frequency | 1…16 kHz adjustable 12…16 kHz with derating factor |
asynchronous motor control | Flux vector control without sensor, standard Voltage/frequency ratio, 5 points Voltage/frequency ratio – Energy Saving, quadratic U/f Voltage/frequency ratio, 2 points |
synchronous motor control profile | Vector control without sensor, standard |
communication port protocol | Modbus CANopen |
type of polarization | No impedance for Modbus |
option card of ATV61HD55N4 original Schneider inverter | Communication card for APOGEE FLN Communication card for BACnet Communication card for CC-Link Controller inside programmable card Communication card for DeviceNet Communication card for EtherNet/IP Communication card for Fipio I/O extension card Communication card for Interbus-S Communication card for LonWorks Communication card for METASYS N2 Communication card for Modbus Plus Communication card for Modbus TCP Communication card for Modbus/Uni-Telway Multi-pump card Communication card for Profibus DP Communication card for Profibus DP V1 |
product destination | Asynchronous motors Synchronous motors |
power supply voltage limits | 323…528 V |
power supply frequency | 50…60 Hz – 5…5 % |
power supply frequency limits | 47.5…63 Hz |
continuous output current | 116 A at 12 kHz, 380 V – 3 phases 96 A at 12 kHz, 460 V – 3 phases |
Output frequency | 0.1…500 Hz |
speed range | 1…100 in open-loop mode, without speed feedback |
speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback |
torque accuracy | +/- 15 % in open-loop mode, without speed feedback |
transient overtorque | 130 % of nominal motor torque +/- 10 % for 60 s |
braking torque | <= 125 % with braking resistor 30 % without braking resistor |
regulation loop | Frequency PI regulator |
motor slip compensation | Not available in voltage/frequency ratio (2 or 5 points) Adjustable Automatic whatever the load Can be suppressed |
diagnostic | 1 LED (red) for drive voltage |
output voltage | <= power supply voltage |
electrical isolation | Between power and control terminals |
type of cable for mounting in an enclosure | With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR |
electrical connection | Terminal 2.5 mm² / AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR) Terminal 150 mm² / 300 kcmil (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
tightening torque | 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR) 41 N.m, 360 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
supply of ATV61HD55N4 original Schneider inverter | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 %, <10 mA with overload and short-circuit protection Internal supply: 24 V DC (21…27 V), <200 mA with overload and short-circuit protection External supply: 24 V DC (19…30 V) |
analogue input number | 2 |
analogue input type | AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign AI2 software-configurable current: 0…20 mA, impedance: 242 Ohm, resolution 11 bits AI2 software-configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits |
sampling time | 2 ms +/- 0.5 ms (AI1-/Al1+) – analog input 2 ms +/- 0.5 ms (Al2) – analog input 2 ms +/- 0.5 ms (AO1) – analog output 2 ms +/- 0.5 ms (LI1…LI5) – discrete input 2 ms +/- 0.5 ms (LI6)if configured as logic input – discrete input |
absolute accuracy precision | +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C +/- 0.6 % (AI2) for a temperature variation 60 °C +/- 1 % (AO1) for a temperature variation 60 °C |
linearity error | +/- 0.15 % of maximum value (AI1-/Al1+) +/- 0.15 % of maximum value (AI2) +/- 0.2 % (AO1) |
analogue output number | 1 |
analogue output type | AO1 software-configurable current, analogue output range 0…20 mA, impedance: 500 Ohm, resolution 10 bits AO1 software-configurable voltage, analogue output range 0…10 V DC, impedance: 470 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V, 20 mA |
discrete output number | 2 |
discrete output type | Configurable relay logic: (R1A, R1B, R1C) NO/NC – 100000 cycles Configurable relay logic: (R2A, R2B) NO – 100000 cycles |
maximum response time | <= 100 ms in STO (Safe Torque Off) R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms R2A, R2B <= 7 ms, tolerance +/- 0.5 ms |
minimum switching current | 3 mA at 24 V DC for configurable relay logic |
maximum switching current | R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms R1, R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms R1, R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms |
discrete input number | 7 |
discrete input type | Programmable (LI1…LI5)24 V DC (<= 30 V), with level 1 PLC – 3500 Ohm Switch-configurable (LI6)24 V DC (<= 30 V), with level 1 PLC – 3500 Ohm Switch-configurable PTC probe (LI6)0…6 probes – 1500 Ohm Safety input (PWR)24 V DC (<= 30 V) – 1500 Ohm |
discrete input logic | Negative logic (sink) (LI1…LI5), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (LI1…LI5), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1) |
acceleration and deceleration ramps | Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 9000 s S, U or customized |
braking to standstill | By DC injection |
protection type | Against exceeding limit speed: drive Against input phase loss: drive Break on the control circuit: drive Input phase breaks: drive Line supply overvoltage: drive Line supply undervoltage: drive Overcurrent between output phases and earth: drive Overheating protection: drive Overvoltages on the DC bus: drive Power removal: drive Short-circuit between motor phases: drive Thermal protection: drive Motor phase break: motor Power removal: motor Thermal protection: motor |
insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
frequency resolution | Analog input: 0.024/50 Hz Display unit: 0.1 Hz |
connector type | 1 RJ45 (on front face) for Modbus 1 RJ45 (on terminal) for Modbus Male SUB-D 9 on RJ45 for CANopen |
physical interface | 2-wire RS 485 for Modbus |
transmission frame | RTU for Modbus |
transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal 9600 bps, 19200 bps for Modbus on front face 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen |
data format | 8 bits, 1 stop, even parity for Modbus on front face 8 bits, odd even or no configurable parity for Modbus on terminal |
number of addresses | 1…127 for CANopen 1…247 for Modbus |
method of access | Slave CANopen |
Marking of ATV61HD55N4 original Schneider inverter | CE |
operating position | Vertical +/- 10 degree |
Net weight | 44 kg |
width of ATV61HD55N4 original Schneider inverter | 320 mm |
Height of ATV61HD55N4 original Schneider inverter | 630 mm |
Depth of ATV61HD55N4 original Schneider inverter | 290 mm |
noise level | 63.7 dB conforming to 86/188/EEC |
dielectric strength | 3535 V DC between earth and power terminals 5092 V DC between control and power terminals |
electromagnetic compatibility | Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
Standards of ATV61HD55N4 original Schneider inverter | EN 55011 class A group 2 EN/IEC 61800-3 EN/IEC 61800-5-1 UL Type 1 IEC 60721-3-3 class 3C1 EN 61800-3 environments 2 category C3 EN 61800-3 environments 1 category C3 IEC 60721-3-3 class 3S2 |
product certifications | UL DNV GOST NOM 117 CSA C-Tick |
pollution degree | 3 conforming to EN/IEC 61800-5-1 3 conforming to UL 840 |
degree of proctection | IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP54 on lower part conforming to EN/IEC 60529 IP54 on lower part conforming to EN/IEC 61800-5-1 |
vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
ambient air temperature for operation | -10…50 °C (without derating) 50…60 °C (with derating factor) |
Ambient air temperature for storage | -25…70 °C |
operating altitude | <= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 46.5 cm |
Package 1 Width | 80.0 cm |
Package 1 Length | 60.0 cm |
Package 1 Weight | 55.5 kg |
Warranty of ATV61HD55N4 original Schneider inverter | 18 months |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”