ATV930U07N4 (Z) inverter, light load 0.75kw heavy load 0.37kw spot
- Name: ATV930U07N4 (Z) inverter, light load 0.75kw heavy load 0.37kw spot
- Brand: Schneider
- Model: ATV930U07N4
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER ATV930U07N4 (Z) inverter, light load 0.75kw heavy load 0.37kw spot
Range of product | Altivar Process ATV900 |
---|---|
Device application | Industrial application |
Product or component type | Variable speed drive |
Product destination | Asynchronous motors Synchronous motors |
Product specific application | Process for industrial |
Variant of ATV930U07N4 (Z) inverter | Standard version With braking chopper |
network number of phases | 3 phases |
Mounting mode | Wall mount |
Communication port protocol | Modbus TCP EtherNet/IP Modbus serial |
[Us] rated supply voltage | 380…480 V – 15…10 % |
motor power kW | 0.75 kW for normal duty 0.37 kW for heavy duty |
motor power hp | 1.0 hp for normal duty 0.5 hp for heavy duty |
continuous output current | 2.2 A at 4 kHz for normal duty 1.5 A at 4 kHz for heavy duty |
EMC filter of ATV930U07N4 (Z) inverter | Integrated With EMC plate option |
IP degree of protection | IP21 |
degree of protection | UL type 1 |
option module | Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for EtherCAT Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A/slot B/slot C: digital and analog I/O extension module Slot A/slot B/slot C: output relay extension module Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module communication module for Ethernet Powerlink |
Discrete input logic | 16 preset speeds |
Asynchronous motor control profile | Constant torque standard Optimized torque mode Variable torque standard |
Synchronous motor control profile | Permanent magnet motor Synchronous reluctance motor |
Maximum output frequency | 599 Hz |
switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
Nominal switching frequency | 4 kHz |
line current of ATV930U07N4 (Z) inverter | 1.5 A at 380 V (normal duty) 0.9 A at 380 V (heavy duty) 1.3 A at 480 V (normal duty) 0.8 A at 480 V (heavy duty) |
apparent power | 1.1 kVA at 480 V (normal duty) 0.7 kVA at 480 V (heavy duty) |
maximum transient current | 2.6 A during 60 s (normal duty) 2.3 A during 60 s (heavy duty) |
Network frequency | 50…60 Hz |
Prospective line Isc | 50 kA |
Discrete input number | 10 |
discrete input type | DI1…DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
Discrete output number | 2 |
discrete output type | Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA Logic output DQ- 0…1 kHz <= 30 V DC 100 mA |
Analogue input number | 3 |
analogue input type | AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA/4…20 mA, impedance: 250 Ohm, resolution 12 bits |
Analogue output number | 2 |
analogue output type | Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0…20 mA impedance 500 Ohm, resolution 10 bits |
Relay output number | 3 |
relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
maximum switching current | Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
Physical interface | Ethernet 2-wire RS 485 |
Connector type of ATV930U07N4 (Z) inverter | 2 RJ45 1 RJ45 |
method of access | Slave Modbus TCP |
Transmission rate | 10, 100 Mbits 4.8 kbps 9600 bit/s 19200 bit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format of ATV930U07N4 (Z) inverter | 8 bits, configurable odd, even or no parity |
Type of polarization | No impedance |
4 quadrant operation possible | True |
Acceleration and deceleration ramps | Linear adjustable separately from 0.01…9999 s |
Motor slip compensation | Not available in permanent magnet motor law Can be suppressed Automatic whatever the load Adjustable |
Braking to standstill | By DC injection |
Brake chopper integrated | True |
Maximum input current | 1.5 A |
Maximum output voltage | 480.0 V |
Relative symmetric network frequency tolerance | 5 % |
Base load current at high overload | 1.5 A |
Base load current at low overload | 2.2 A |
power dissipation in W | Natural convection: 26 W at 380 V, switching frequency 4 kHz Forced convection: 21 W at 380 V, switching frequency 4 kHz |
With safety function Safely Limited Speed (SLS) | True |
With safety function Safe brake management (SBC/SBT) | True |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | True |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | True |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
protection type of ATV930U07N4 (Z) inverter | Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
Quantity per set | 1 |
Width of ATV930U07N4 (Z) inverter | 144 mm |
Height of ATV930U07N4 (Z) inverter | 350 mm |
Depth of ATV930U07N4 (Z) inverter | 206 mm |
Product weight | 4.5 kg |
electrical connection | Control: screw terminal 0.5…1.5 mm²/AWG 20…AWG 16 Line side: screw terminal 2.5…6 mm²/AWG 14…AWG 10 Motor: screw terminal 2.5…6 mm²/AWG 14…AWG 10 DC bus: screw terminal 2.5…6 mm²/AWG 14…AWG 10 |
transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
data format | 8 bits, configurable odd, even or no parity for Modbus serial |
type of polarization | No impedance for Modbus serial |
number of addresses | 1…247 for Modbus serial |
supply of ATV930U07N4 (Z) inverter | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
local signalling of ATV930U07N4 (Z) inverter | Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red) |
input compatibility | DI1…DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
discrete input logic | Positive logic (source) (DI1…DI8), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1…DI8), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
sampling duration | 2 ms +/- 0.5 ms (DI1…DI8) – discrete input 5 ms +/- 1 ms (DI7, DI8) – pulse input 1 ms +/- 1 ms (AI1, AI2, AI3) – analog input 5 ms +/- 1 ms (AQ1, AQ2) – analog output |
accuracy of ATV930U07N4 (Z) inverter | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
linearity error of ATV930U07N4 (Z) inverter | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
refresh time of ATV930U07N4 (Z) inverter | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Isolation of ATV930U07N4 (Z) inverter | Between power and control terminals |
operating altitude | <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m |
Operating position | Vertical +/- 10 degree |
Product certifications | CSA UL TÜV |
Marking of ATV930U07N4 (Z) inverter | CE |
Standards of ATV930U07N4 (Z) inverter | UL 508C EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
maximum THDI | <48 % full load conforming to IEC 61000-3-12 |
Assembly style of ATV930U07N4 (Z) inverter | Enclosed |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
Volume of cooling air | 38 m3/h |
Overvoltage category | III |
Regulation loop | Adjustable PID regulator |
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
noise level | 54.5 dB conforming to 86/188/EEC |
vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
ambient air temperature for operation | -15…50 °C (without derating) 50…60 °C (with derating factor) |
Noise level | 54.5 dB |
Pollution degree | 2 |
Ambient air transport temperature | -40…70 °C |
Ambient air temperature for storage | -40…70 °C |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”