Inverter ATV312 series 7.5kW three-phase spot
- Name: Inverter ATV312 series 7.5kW three-phase spot
- Brand: Schneider
- Model: ATV312HU75M3
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF ATV312HU75M3 inverter, ATV312 series 7.5kW three-phase spot
Range of product | Altivar 312 |
---|---|
Product or component type | Variable speed drive |
Product destination of Inverter ATV312 | Asynchronous motors |
Product specific application | Simple machine |
Assembly style | With heat sink |
Component name of Inverter ATV312 | ATV312 |
Motor power kW | 7.5 kW |
Motor power hp | 10 hp |
[Us] rated supply voltage | 200…240 V – 15…10 % |
Supply frequency of Inverter ATV312 | 50…60 Hz – 5…5 % |
Network number of phases | 3 phases |
Line current of Inverter ATV312 | 46.8 A at 200 V, Isc = 22 kA 40.9 A at 240 V |
EMC filter of Inverter ATV312 | Without EMC filter |
Apparent power of Inverter ATV312 | 16.2 kVA |
Maximum transient current | 49.5 A for 60 s |
Power dissipation in W | 388 W at nominal load |
Speed range of Inverter ATV312 | 1…50 |
Asynchronous motor control profile | Sensorless flux vector control with PWM type motor control signal Factory set : constant torque |
Electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 terminal 2.5 mm² AWG 14 L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 16 mm² AWG 6 |
Supply | Internal supply for logic inputs: 19…30 V 100 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (2.2 to 10 kOhm): 10…10.8 V 10 mA, protection type: overload and short-circuit protection |
Communication port protocol | CANopen Modbus |
IP degree of protection | IP20 on upper part without cover plate IP21 on connection terminals IP31 on upper part IP41 on upper part |
Option card | Communication card for CANopen daisy chain Communication card for DeviceNet Communication card for Fipio Communication card for Modbus TCP Communication card for Profibus DP |
Supply voltage limits | 170…264 V |
Prospective line Isc | 22 kA |
Continuous output current | 33 A at 4 kHz |
Output frequency | 0…500 Hz |
Nominal switching frequency | 4 kHz |
Switching frequency | 2…16 kHz adjustable |
Transient overtorque | 170…200 % of nominal motor torque |
Braking torque | 150 % during 60 s with braking resistor 100 % with braking resistor continuously 150 % without braking resistor |
Regulation loop | Frequency PI regulator |
Motor slip compensation | Automatic whatever the load Suppressable Adjustable |
Output voltage | <= power supply voltage |
Tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6: 0.6 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 2.5 N.m |
Insulation | Electrical between power and control |
Analogue input number | 3 |
Analogue input type | AI1 configurable voltage 0…10 V, input voltage 30 V max, impedance: 30000 Ohm AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm AI3 configurable current 0…20 mA, impedance: 250 Ohm |
Sampling duration | AI1, AI2, AI3: 8 ms analog LI1…LI6: 4 ms discrete |
Response time | AOV, AOC 8 ms for analog R1A, R1B, R1C, R2A, R2B 8 ms for discrete |
Linearity error | +/- 0.2 % for output |
Analogue output number | 1 |
Analogue output type | AOC configurable current: 0…20 mA, impedance: 800 Ohm, resolution: 8 bits AOV configurable voltage: 0…10 V, impedance: 470 Ohm, resolution: 8 bits |
Discrete input logic | Logic input not wired (LI1…LI4), < 13 V (state 1) Negative logic (source) (LI1…LI6), > 19 V (state 0) Positive logic (source) (LI1…LI6), < 5 V (state 0), > 11 V (state 1) |
Discrete output number | 2 |
Discrete output type | Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC – 100000 cycles Configurable relay logic: (R2A, R2B) NC – 100000 cycles |
Minimum switching current | R1-R2 10 mA at 5 V DC |
Maximum switching current | R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms |
Discrete input number | 6 |
Discrete input type | (LI1…LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm |
Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.1 to 999.9 s |
Braking to standstill | By DC injection |
Protection type | Input phase breaks: drive Line supply overvoltage and undervoltage safety circuits: drive Line supply phase loss safety function, for three phases supply: drive Motor phase breaks: drive Overcurrent between output phases and earth (on power up only): drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: motor |
Insulation resistance | >= 500 mOhm 500 V DC for 1 minute |
Local signalling | 1 LED (red) for drive voltage Four 7-segment display units for CANopen bus status |
Time constant | 5 ms for reference change |
Frequency resolution | Analog input: 0.1…100 Hz Display unit: 0.1 Hz |
Connector type | 1 RJ45 for Modbus/CANopen |
Physical interface | RS485 multidrop serial link |
Transmission frame | RTU |
Transmission rate | 10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen 4800, 9600 or 19200 bps for Modbus |
Number of addresses | 1…127 for CANopen 1…247 for Modbus |
Number of drive | 127 for CANopen 31 for Modbus |
Marking | CE |
Operating position | Vertical +/- 10 degree |
Outer dimension | 232 x 180 x 170 mm |
Height | 232 mm |
Width | 180 mm |
Depth | 172 mm |
Net weight | 6.4 kg |
Dielectric strength of Inverter ATV312 | 2040 V DC between earth and power terminals 2880 V AC between control and power terminals |
Electromagnetic compatibility | 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Standards of Inverter ATV312 | IEC 61800-3 IEC 61800-5-1 |
Product certifications | CSA DNV C-Tick UL NOM GOST |
Pollution degree | 2 |
Protective treatment | TC |
Vibration resistance of Inverter ATV312 | 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Relative humidity of Inverter ATV312 | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Ambient air temperature for storage | -25…70 °C |
Ambient air temperature for operation | -10…50 °C without derating (with protective cover on top of the drive) -10…60 °C with derating factor (without protective cover on top of the drive) |
Operating altitude of Inverter ATV312 | <= 1000 m without derating 1000…3000 m with current derating 1 % per 100 m |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”