ATV320U06M2C/B inverter, ATV320 single-phase 220V 0.55kw spot
- Name: ATV320U06M2C/B inverter, ATV320 single-phase 220V 0.55kw spot
- Brand: Schneider
- Model: ATV320U06M2C
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF Schneider ATV320U06M2C/B inverter, ATV320 single-phase 220V 0.55kw spot
range of product | Altivar Machine ATV320 |
---|---|
product or component type | Variable speed drive |
product specific application | Complex machines |
variant | Standard version |
format of the drive | Compact |
mounting mode | Wall mount |
communication port protocol | Modbus serial CANopen |
option card of ATV320U06M2C | Communication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, PROFINET Communication module, Ethernet Powerlink Communication module, EtherNet/IP Communication module, DeviceNet |
[Us] rated supply voltage | 200…240 V – 15…10 % |
nominal output current | 3.7 A |
motor power kW | 0.55 kW for heavy duty |
EMC filter of ATV320U06M2C | Class C2 EMC filter integrated |
IP degree of protection | IP20 |
discrete input number | 7 |
discrete input type | STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1…DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
discrete input logic | Positive logic (source) Negative logic (sink) |
discrete output number | 3 |
discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA |
analogue input number | 3 |
analogue input type | AI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
analogue output number | 1 |
analogue output type | Software-configurable current AQ1: 0…20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
relay output type | Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C |
maximum switching current | Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
method of access of ATV320U06M2C | Slave CANopen |
4 quadrant operation possible | True |
asynchronous motor control profile | Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio – Energy Saving, quadratic U/f Flux vector control without sensor – Energy Saving Voltage/frequency ratio, 2 points |
synchronous motor control profile | Vector control without sensor |
maximum output frequency | 0.599 kHz |
transient overtorque | 170…200 % of nominal motor torque |
acceleration and deceleration ramps | Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection |
motor slip compensation | Automatic whatever the load Adjustable 0…300 % Not available in voltage/frequency ratio (2 or 5 points) |
switching frequency | 2…16 kHz adjustable 4…16 kHz with derating factor |
nominal switching frequency | 4 kHz |
braking to standstill | By DC injection |
brake chopper integrated | True |
line current of ATV320U06M2C | 7.8 A at 200 V (heavy duty) 6.6 A at 240 V (heavy duty) |
maximum input current | 7.8 A |
maximum output voltage | 240 V |
apparent power of ATV320U06M2C | 1.6 kVA at 240 V (heavy duty) |
network frequency | 50…60 Hz |
relative symmetric network frequency tolerance | 5 % |
prospective line Isc | 1 kA |
base load current at high overload | 1.5 A |
power dissipation in W | Self-cooled: 33.0 W at 200 V, switching frequency 4 kHz |
with safety function Safely Limited Speed (SLS) | True |
with safety function Safe brake management (SBC/SBT) | False |
with safety function Safe Operating Stop (SOS) | False |
with safety function Safe Position (SP) | False |
with safety function Safe programmable logic | False |
with safety function Safe Speed Monitor (SSM) | False |
with safety function Safe Stop 1 (SS1) | True |
with sft fct Safe Stop 2 (SS2) | False |
with safety function Safe torque off (STO) | True |
with safety function Safely Limited Position (SLP) | False |
with safety function Safe Direction (SDI) | False |
protection type | Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive |
width of ATV320U06M2C | 72.0 mm |
height of ATV320U06M2C | 143.0 mm |
depth of ATV320U06M2C | 138.0 mm |
net weight of ATV320U06M2C | 1.1 kg |
operating position | Vertical +/- 10 degree |
product certifications | CE ATEX NOM GOST EAC RCM KC |
marking of ATV320U06M2C | CE ATEX UL CSA EAC RCM |
standards of ATV320U06M2C | EN/IEC 61800-5-1 |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13…200 Hz |
maximum deflection under vibratory load (during operation) | 1.5 mm at 2…13 Hz |
permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
overvoltage category | III |
regulation loop | Adjustable PID regulator |
speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
pollution degree | 2 |
ambient air transport temperature | -25…70 °C |
ambient air temperature for operation | -10…50 °C without derating 50…60 °C with derating factor |
ambient air temperature for storage | -25…70 °C |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 11.5 cm |
Package 1 Width | 18.7 cm |
Package 1 Length | 19 cm |
Package 1 Weight | 1.339 kg |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 45 |
Package 2 Height | 75 cm |
Package 2 Width | 60 cm |
Package 2 Length | 80 cm |
Package 2 Weight | 72.895 kg |
Package 3 Height | 80 cm |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”