Item
Specification
Overload Capacity 150% for 60 sec. (HD), 110% for 60 sec. (ND)
Output Frequency 0~590 Hz
Control Methods Open and Closed Loop Current Vector;
Open and Closed Loop V/f
Motor Types Induction
Surface Permanent Magnet
Interior Permanent Magnet
Synchronous Reluctance
Protective Design IP20 (IP20/UL Type 1 kit available)
Flange (IP55/UL Type 12 backside)
Protective Design
and
Ambient Operating Temperature
IP20/Protected Chassis(-10 to +50°C)
IP20 with UL Type 1 kit (-10 to +40°C)
Flange: front = IP20/Protected Chassis(-10 to +50°C);
back = IP55/UL Type12 (-10 to +40°C)
All types (additional +10°C with derate)
Global Certification UL, CSA, CE, RCM, RoHS
Functional Safety Safe Torque Off, SIL3 according to IEC 62061, PLe according to ISO 13849-1
(600V models pending, consult factory)
Standard I/O (8) multi-function digital inputs (24Vdc)
(3) multi-function analog inputs (0 +/- 10 VDC, 4-20 mA)
(1) multi-function pulse inputs
(2) Safe Torque Off inputs
(1) fault relay output (form C)
(3) multi-function relay outputs (form A)
(2) multi-function analog output (0 +/- 10 VDC, 4-20mA)
(1) multi-function pulse output
I/O Expansion (3) Analog Inputs -10 to +10V, 13 bit plus sign, 4 to 20mA
(16) Digital Inputs
(2) Analog Outputs (-10 to +10V, 11 bit magnitude)
(8) Digital Outputs (6 transistor, 2 relay)
Feedback Incremental
Absolute (Stegmann, Heidenhain, Resolver)
Network Communication Standard: Modbus RTU, RS-485, 115 kbps

Optional: EtherNet/IP, DeviceNet, Modbus TCP/IP, PROFINET, PROFIBUS-DP

Speed Control Range 1500:1 Closed Loop Vector (IM and PM Motors)
200:1 Open Loop Vector (IM Motors)
100:1 Open Loop Vector (PM Motors)
Speed Control Accuracy ≤ 0.02%: Closed Loop Vector; ≤ 0.2%; Open Loop Vector
Speed Response ≥ 50 Hz: Closed Loop Vector (Induction Motors)
≥ 250 Hz: Closed Loop Vector (PM Motors)
≥ 20 Hz: Open Loop Vector (Induction Motors)
≥ 40 Hz: Open Loop Vector (PM Motors)
Function Block Diagrams Up to 200 connections, 500us program scan time

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us