PRODUCT INFORMATION OF Keyence base unit KV-NC32T.
Model | KV-NC32T | |||
General specifications | Power voltage | 24 VDC (+10%/-15%) | ||
Operating ambient temperature | 0 to 55°C 32 to 131°F (no freezing)*1 | |||
Operating ambient humidity | 5 to 95% RH (no condensation) | |||
Operating environment | As little dust and corrosive gas as possible | |||
Noise immunity | 1500 V peak-to-peak or more, pulse duration 1 μs, 50 ns (based on noise simulator) Conforms to IEC standards (IEC61000-4-2/3/4/6) |
|||
Withstand voltage | 1500 VAC for 1 minute, between power supply terminal and I/O terminals and between all external terminals and case (1000 VAC for 1 minute, between power supply terminal and output terminals for the transistor output type expansion I/O unit) |
|||
Insulation resistance | 50 MΩ or more (500 VDC megger used to perform measurements between power supply terminal and input terminals, and between all external terminals and case) |
|||
Storage temperature | −25 to +75°C −13 to +167°F | |||
Vibration resistance | Intermittent vibration | Frequency: 5 to 9 Hz | Amplitude: 3.5 mm 0.14″*2 | |
Frequency: 9 to 150 Hz | Acceleration: 9.8 m/s2 32.2’/s2*2 | |||
Continuous vibration | Frequency: 5 to 9 Hz | Amplitude: 1.75 mm 0.07″*2 | ||
Frequency: 9 to 150 Hz | Acceleration: 4.9 m/s2 16.1’/s2*2 | |||
Shock resistance | Acceleration: 150 m/s2 492.1’/s2, application time: 11 ms, three times in each of the X, Y, and Z directions | |||
Operating altitude | 2000 m 6561.7′ or less | |||
Overvoltage category | I | |||
Pollution degree | 2 | |||
Performance specifications | Calculation control method | Program storage method | ||
I/O control method | Refresh method | |||
Program language | Expanded ladder, KV Script, mnemonic | |||
Number of instructions | Basic instruction: 81 types and 182 instructions, Application instruction: 39 types and 56 instructions Calculation instruction: 123 types and 311 instructions, Expansion instruction: 92 types and 141 instructions Total: 335 types and 690 instructions |
|||
Instruction execution speed | Basic instruction: 50 ns minimum, Application instruction: 170 ns minimum | |||
Program capacity | 32k steps | |||
Maximum number of attachable I/O units | 8 | |||
Maximum number of I/O points | 256 | |||
Input relay/Output relay/Internal auxiliary relay | R | Total of 9600 points 1 bit (R000 to R59915) | ||
Link relay | B | 8192 points 1 bit (B0 to B1FFF) | ||
Internal auxiliary relay | MR | 9600 points 1 bit (MR000 to MR59915) | ||
Latch relay | LR | 3200 points 1 bit (LR000 to LR19915) | ||
Control relay | CR | 1440 points 1 bit (CR000 to CR8915) | ||
Timer | T | 512 points 32 bits (T0 to T511) | ||
Counter | C | 256 points 32 bits (C0 to C255) | ||
Data memory | DM | 32768 points 16 bit (DM0 to DM32767) | ||
Link register | W | 16384 points 16 bit (W0 to W3FFF) | ||
Temporary memory | TM | 512 points 16 bit (TM0 to TM511) | ||
High-speed counter | CTH | 3 points (CTH0 to CTH2) 32-bit automatic reset counter*3 (Input response: 100 kHz per single phase, 50 kHz per phase difference)*4 |
||
High-speed counter comparator | CTC | 6 points (CTC0 to CTC5) 32 bits, two points per high-speed counter |
||
Index register | Z | 12 points 32 bit (Z01 to Z12) | ||
Control memory | CM | 9000 points 16 bit (CM0 to CM8999) | ||
Positioning pulse output | 3 axes Maximum output frequency: 100 kHz |
|||
Base unit I/O | Input: 16 points output: 16 points Input common: 1 point Output common: 1 point |
|||
Number of comments and labels that can be stored in the main unit | Device comment | 20000 When a maximum-length ladder program is written with no labels. |
||
Label | 28000 When a maximum-length ladder program is written with no device comments. |
|||
Power off hold function | Program memory | Flash ROM can be rewritten 10000 times | ||
Device | Nonvolatile RAM*5 | |||
Clock function | ±60 seconds/month (at 25°C 77°F) | |||
Self-diagnosis function | CPU error, RAM error, and other problems | |||
Input specifications | Relay number | General input: R000 to R009 (10 points), High-speed A-phase and B-phase input: R010 to R015 (6 points) | ||
Input mode | 24 VDC input (open collector) | |||
Maximum input voltage | 26.4 VDC | |||
Rated input voltage | 24 VDC (General input: 5.3 mA, High-speed A-phase and B-phase input: 6.5 mA*6) | |||
Minimum ON voltage | 19 VDC | |||
Maximum OFF current | 1.5 mA | |||
Common method | All points/1 common (1 terminal) | |||
Circuit delay time | General input: OFF to ON: Max. 30 μs (Typ. 3.5 μs), ON to OFF: Max. 50 μs (Typ. 15 μs) High-speed A-phase and B-phase input: OFF to ON: Max. 2 μs (Typ. 1.1 μs), ON to OFF: Max. 2 μs (Typ. 0.3 μs) *7 |
|||
Input time constant | Normal: 10 ms, When the HSP instruction is used: 10 μs When CR2305 is turned ON: 10 μs to 10 ms, eight-level switching is possible (set with CM1620). Can also be set from the Unit Editor.*7 |
|||
Delay by input time constant Input time constant setting 10 μs: Digital filter 1.6 to 2 μs Input time constant setting 20 μs: Digital filter 9 to 12 μs Input time constant setting 110 μs: Digital filter 90 to 93 μs Input time constant setting 500 μs: Digital filter 300 to 400 μs Input time constant setting 1 ms: Digital filter 800 to 900 μs Input time constant setting 2.5 ms: Digital filter 2.3 to 2.4 ms Input time constant setting 5 ms: Digital filter 4.0 to 4.5 ms Input time constant setting 10 ms: Digital filter 9 to 9.5 ms |
||||
Response frequency | (High-speed A-phase and B-phase input) Single phase: 100 kHz, phase difference: 50 kHz, 24 V ±10%, Duty 50% | |||
Output specifications | Relay number | General output: R506 to R515 (10 points), High-speed output: R500 to R505 (6 points) | ||
Output mode | MOSFET (N-ch) output | |||
Rated load | 30 VDC General output: 0.2 A (1.6 A/common), High-speed output: 0.3 A (1.6 A/common) |
|||
Maximum OFF voltage | 30 VDC | |||
Leakage current at OFF | 100 μA or less | |||
Residual voltage at ON | 0.6 VDC or less | |||
Common method | 16 points/1 common | |||
ON/OFF response time | General output: OFF to ON: 100 μs (load of 1 mA or more), ON to OFF: 200 μs (load of 1 mA or more) High-speed output: OFF to ON: 2 μs (load of 7 mA or more), ON to OFF: 5 μs (load of 7 mA or more) |
|||
Overcurrent protection | Protection provided for each common*8 | |||
Output frequency | High-speed output: 100 kHz (7 to 100 mA load) | |||
Built-in serial port | Interface | Communication standard | RS-232C | |
Connection | Modular connector | |||
Transmission specifications RS-232C | Baud rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps | ||
Transmission method | Full duplex | |||
Data format | Start bit | 1 bit | ||
Data bits | 7 bits, 8 bits | |||
Stop bits | 1 bit, 2 bits | |||
Error detection | Parity | Even, odd, none | ||
Transmission distance | 15 m 49.2′ | |||
Number of transmission units | 1 | |||
Indication | Common between SD/RD SD: (green) RD: (red) The color may appear as orange during transmission. |
|||
Internal current consumption | 260 mA | |||
Weight | Approx. 220 g |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”