LC1D12M7C Schneider LC1D three-level AC contactor AC24 220V 380V.

LC1D12M7C Schneider LC1D three-level AC contactor AC24 220V 380V.

Share to:

Aditional Informations

PRODUCT INFORMATION OF SCHNEIDER LC1D three-level AC contactor LC1D12M7C AC24 220V 380V.

Main Information

Product Series TeSys Deca
Product Series TeSys Deca
product type Contactor
product short name LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category of LC1D12M7C AC-4
AC-1
AC-3
AC-3e
number of poles 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
Rated operating current [Ie] 25 A 60 °C) at <= 440 V AC AC-1 for power circuit
12 A 60 °C) at <= 440 V AC AC-3 for power circuit
12 A 60 °C) at< = 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 230V AC 50/60Hz
Motor power (kW) 7.5 kW at 500 V AC 50/60 Hz (AC-3)
3 kW at 220/240 V AC 50/60 Hz (AC-3)
5.5 kW at 380/400 V AC 50/60 Hz (AC-3)
5.5 kW at 415/440 V AC 50/60 Hz (AC-3)
7.5 kW at 660/690 V AC 50/60 Hz (AC-3)
3.7 kW at 400 V AC 50/60 Hz (AC-4)
7.5 kW at 500 V AC 50/60 Hz (AC-3e)
3 kW at 220/240 V AC 50/60 Hz (AC-3e)
5.5 kW at… at 380/400 V AC 50/60 Hz (AC-3e)
5.5 kW at 415/440 V AC 50/60 Hz (AC-3e)
7.5 kW at 660/690 V AC 50/60 Hz (AC -3e)
model of LC1D12M7C LC1D
Loop contact type 3 NO
protection cap None
Conventional thermal current [Ith] 25 A at <60 °C for power circuits
10 A at <60 °C for signal circuits
Rated short-time withstand current [Icw] 105 A at <40 °C – 10 s for power circuit
210 A at <40 °C – 1 s for power circuit
30 A at <40 °C – 10 min for power circuit
61 A at <40 °C – 1 minute for power circuit
100 A – 1 s for signal circuit
120 A – 500 ms for signal circuit
140 A – 100 ms for signal circuit
Fuses for use with relays 10 A gG for signal circuits according to IEC 60947-5-1
40 A gG at <= 690 V for power circuits type 1
25 A gG for power circuits for type 2 at <= 690 V
average impedance 2.5 mΩ – Ith 25 A 50 Hz for power loop
Rated insulation voltage [Ui] Power circuit: 690 V conforming to IEC 60947-4-1
Signal circuit: 690 V conforming to IEC 60947-1
Overvoltage category III
pollution level 3
Rated impulse withstand voltage [Uimp] 6 kV according to IEC 60947
Safety and reliability level B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1
Mechanical life 15 Mcycles
Electrical life 2 Mcycles 12 A AC-3 Ue <= 440 V
0.8 Mcycles 25 A AC-1 Ue <= 440 V
2.2 Mcycles 9 A AC-3 Ue 660/690 V
2 Mcycles 12 A AC-3e Ue <= 440 V
at 2.2 Mcycles 9 A AC-3e at 660/690 V at Ue
Control loop characteristics AC at 50/60 Hz
Surge Suppression Module No built-in surge suppression module
Control voltage limit 0.3…0.6 Uc -40…60 °C release 50/60 Hz
0.8…1.1 Uc -40…60 °C run 50 Hz
0.85…1.1 Uc -40…60 °C run 60 Hz
(~50Hz pickup) power consumption (VA) 70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
(~50Hz hold) power consumption (VA) 7.5 VA 60 Hz 0.3 20 °C)
7 VA 50 Hz 0.3 20 °C)
heat dissipation 2…3 W at 50/60 Hz
action time of LC1D12M7C 12…22 ms close
4…19 ms break
operating frequency 3600 cycles/h at <60 °C
Wiring capacity Power circuit: screw fastening1 1…4 mm² Lug O.D. Ø: 8 mm Cable option: flexible cord without wire terminal
Power Circuit: screw fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable Selection: flexible cord without wire terminals
Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable selection: flexible cord with wire terminal
Power circuit: screw fastening2 1…2.5 mm² Lug outer diameter Ø: 8 mm Cable option: flexible with wire terminals
Power circuit: screw fastening1 1…4 mm² Lug outer diameter Ø: 8 mm Cable option: Solid without wire terminals
Power circuit : Bolt fastening2 1…4 mm² Lug O.D. Ø: 8 mm Cable option: Rigid without wire terminals
Control circuit: Bolt tight1 1…4 mm² Cable option: Flexible wire without wire terminals
Control circuit: screw-on2 1…4 mm² Cable option: flexible without cable terminals
Control circuit: screw-on1 1…4 mm² cable option: flexible with cable terminals
Control circuit: screw -on2 1…2.5 mm² cable selection: flexible wire with wire terminals
control circuit: screw fastened1 1…4 mm² cable selection: rigid without wire terminal
control circuit: screw fastened2 1…4 mm² cable selection : Hard wire without wire terminal
Tightening torque Power circuit: 1.7 Nm via screwdriver Ø 6 flat
power circuit: 1.7 Nm via screwdriver No 2 Phillips screw
control circuit: 1.7 Nm via screwdriver Ø 6 flat
control circuit: 1.7 Nm via screw Screwdriver No. 2 for fastening Phillips screw
Power circuit: 1.7 Nm Screwdriver Ø 6 flat-blade screw via cable connector: M3.5
Power circuit: 1.7 Nm Phillips screw driver No. 2 via cable connector Screw: M3.5
Control circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening
Power circuit: 1.7 Nm Screwdriver pozidriv No 2 for screw tightening
Auxiliary contact type 1 NO + 1 NC
Auxiliary contact type Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1
Signal loop frequency 25…400Hz
Minimum switching voltage 17 V for signal return
Minimum switching current [Imin] 5 mA for signal loop
Insulation resistance > 10 MΩ for signal loops
non-overlapping time 1.5 ms between de-energized NC and NO contacts
1.5 ms between energized NC and NO contacts
installation method Chassis mounting
rail installation
standard of LC1D12M7C GB 14048.4
IEC 60947-4-1
certified product CCC
CE
UKCA
IP protection class IP2x front panel for main circuits conforming to IEC 60529
IP2x front panel for coil circuits conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-11
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance with contacts closed (4 gn (5…300 Hz)) conforming to IEC
60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
high of LC1D12M7C 77 mm
width of LC1D12M7C 45 mm
depth of LC1D12M7C 86 mm
Product Weight of LC1D12M7C 0.325 kg

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”