LC1D410M7C Schneider LC1D three-level AC contactor AC24 220V 380V.

LC1D410M7C Schneider LC1D three-level AC contactor AC24 220V 380V.

Share to:

Aditional Informations

PRODUCT INFORMATION OF SCHNEIDER LC1D three-level AC contactor LC1D410M7C AC24 220V 380V.

Main

Product Series TeSys Deca
Product Series TeSys Deca
product type Contactor
product short name LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category of LC1D410M7C AC-
3AC-1
number of poles 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 500 A 40 °C) at <= 440 V AC AC-1 for power circuits
410 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 230V AC 50/60Hz
Motor power (kW) 110 kW at 220/240 V AC 50/60 Hz (AC-3)
220 kW at 380/400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660/690 V AC 50 /60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
model of LC1D410M7C LC1D
Loop contact type 3 NO
protection cap None
Conventional thermal current [Ith] 500 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 3600 A at <40 °C – 10 s for power circuit
2400 A at <40 °C – 30 s for power circuit
1700 A at <40 °C – 1 min for power circuit
1200 A at <40 °C – 3 minutes for power circuits
1000 A at <40 °C – 10 minutes for power circuits
Fuses for use with relays 400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
630 A gG at <= 440 V for power circuits
average impedance 0.26 mΩ – Ith 500 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
pollution level 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947
Mechanical life 8 Mcycles
Electrical life 0.5 Mcycles 500 A AC-1 Ue <= 440 V
0.9 Mcycles 370 A AC-3 Ue <= 440 V
0.7 Mcycles 305 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50/60 Hz
Control voltage limit 0.3…0.5 Uc -5…55 °C release 40…400 Hz
0.85…1.1 Uc -5…55 °C run 40…400 Hz
(~50Hz pickup) power consumption (VA) 1075 VA 50 Hz 0.9 20 °C)
1075 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 15 VA 50 Hz 0.9 20 °C)
15 VA 60 Hz 0.9 20 °C)
heat dissipation 14W
action time of LC1D410M7C 100…170 ms
open 40…75 ms close
operating frequency 2400 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Tightening torque Control circuit: 1.2 Nm Power circuit via bolt fastening
: 35 Nm Power circuit via busbar terminals
: 35 Nm via cable connector
Auxiliary contact type Does not contain
installation method Rail installation
standard of LC1D410M7C IEC 60947-4-1
GB 14048.4
certified product CCC
CE
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None
Shock and vibration resistance Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5 gn) …300 Hz)) conforming to IEC 60068-2-6
shock resistance contact opening (1.5 gn (5…300 Hz)) conforming to IEC 60068-2-6
high of LC1D410M7C 206 mm
width of LC1D410M7C 213mm
depth of LC1D410M7C 219 mm
Product Weight 10.05kg

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”