Omron H7CX-A4-N H7CX-AN electronic counter digital digital display genuine spot
- Name: Omron H7CX-A4-N H7CX-AN electronic counter digital digital display genuine spot
- Brand: Omron
- Model: H7CX-A4-N
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF OMRON H7CX-A4-N H7CX-AN electronic counter digital digital display genuine spot
Function | 1 Stage Preset Counter, Total Preset Counter | |
---|---|---|
Preset stages | 1 step | |
Rated supply voltage | 100 to 240 VAC 50/60 Hz | |
Operating voltage range | 85 to 110% of rated power supply voltage | |
Power consumption | at 100 to 240 VAC: Approx. 9.4 VA | |
External power supply | 12 VDC (±10%), 100 mA | |
Counter | Count range | -999 to 9999 |
Max. counting speed | 30 Hz/10 kHz (switching) Minimum pulse width: 16.7 ms(30 Hz)、0.05 ms(10 kHz) (ON/OFF ratio 1:1) |
|
Input mode | Increment (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)) | |
Output modes | N, F, C, R, K-1, P, Q, A, K-2, D, L | |
One-shot output time | 0.01 to 99.99 s variable | |
Reset system | External, manual and automatic reset (internal according to C, R, P and Q mode operation) | |
Input | Input signal | CP1, CP2, Reset, Total reset |
Input method | No-voltage (NPN)/Voltage input (PNP) selectable | |
No-voltage input (No-contact input) | Short-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. |
|
Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΩ) |
|
Contact input | Use a contact which can adequately switch 5 mA at 10 V. | |
Reset time | External reset | 1 ms/20 ms (selectable) |
Control output | Contact output | SPDT 3 A at 250 VAC/30 VDC, resistive load (cos phi=1) Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value) |
Display | Display method | 7-segment negative transmissive LCD |
Digits | 4 digit | |
Character height | Count value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green) |
|
Prescaling function | 0.001 to 9.999 | |
Decimal point adjustment | Rightmost 3 digits | |
Key protection | Key protect Switch | |
Memory backup methods | Method: EEP-ROM, Number of rewite: 100,000 operations min., Store data: 10 years min. | |
Ambient temperature (Operating) | -10 to 55 ℃ (with no freezing or condensation) Close mounting: -10 to 50 ℃ (with no freezing or condensation) |
|
Ambient temperature (Storage) | -25 to 70 ℃ (with no freezing or condensation) | |
Ambient humidity (Operating) | 25 to 85% | |
Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC) |
|
Dielectric withstand voltage | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min |
|
Impulse withstand voltage | Between power terminals: 3 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
|
Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
|
Static immunity of Omron H7CX-A4-N H7CX-AN | Mulfunction: 8 kV, Destruction: 15 kV | |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min |
|
Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 3 axes each directions |
|
Life expectancy | Mechanical life: 10 million operations min. Electrical life: 100,000 operations min. (3 A at 250 VAC resistive load) |
|
Degree of protection | Case front: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing) | |
External connection method | Screw terminal | |
Case color of Omron H7CX-A4-N H7CX-AN | Black (Munsell N1.5) | |
Accessories | Flush mounting adapter, Waterproof packing, Terminal Cover | |
Weight of Omron H7CX-A4-N H7CX-AN | Approx. 130 g |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”