Schneider ATV310A inverter ATV310H075N4A.
- Name: Schneider ATV310A inverter ATV310H075N4A.
- Brand: Schneider
- Model: ATV310H075N4A
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER original genuine ATV310A inverter ATV310H075N4A.
Range of product | Easy Altivar 310 |
---|---|
Product or component type | Variable speed drive |
Product specific application | Simple machine |
Assembly style of Schneider ATV310A inverter | With heat sink |
Device short name | ATV310 |
Network number of phases | Three phase |
[Us] rated supply voltage | 380…460 V – 15…10 % |
motor power kW | 0.75 kW for heavy duty |
motor power hp | 1 hp for heavy duty |
Product destination | Asynchronous motors |
Quantity per set | Set of 1 |
EMC filter of Schneider ATV310A inverter | Without EMC filter |
supply frequency of Schneider ATV310A inverter | 50/60 Hz +/- 5 % |
Communication port protocol | Modbus |
connector type of Schneider ATV310A inverter | RJ45 (on front face) for Modbus |
physical interface | 2-wire RS 485 for Modbus |
transmission frame | RTU for Modbus |
transmission rate | 4800 bit/s 9600 bit/s 19200 bit/s 38400 bit/s |
number of addresses | 1…247 for Modbus |
communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
line current of Schneider ATV310A inverter | 3.5 A at 380 V (heavy duty) 3.1 A at 460 V (heavy duty) |
apparent power of Schneider ATV310A inverter | 2.5 kVA at 460 V (heavy duty) |
Prospective line Isc | 5 kA |
continuous output current | 2.3 A heavy duty |
maximum transient current | 3.5 A during 60 s (heavy duty) |
power dissipation in W | 28.8 W, at In (heavy duty) |
Speed drive output frequency | 0.5…400 Hz |
Nominal switching frequency | 4 kHz |
switching frequency | 2…12 kHz adjustable |
speed range of Schneider ATV310A inverter | 1…20 |
transient overtorque | 170…200 % of nominal motor torque depending on drive rating and type of motor |
braking torque | Up to 150 % of nominal motor torque with braking resistor at high inertia Up to 70 % of nominal motor torque without braking resistor |
Asynchronous motor control profile | Sensorless flux vector control Energy saving ratio Quadratic voltage/frequency ratio |
Motor slip compensation | Preset in factory Adjustable |
output voltage of Schneider ATV310A inverter | 380…460 V three phase |
electrical connection | Terminal, clamping capacity: 1.5…2.5 mm² (L1, L2, L3, PA/+, PB, U, V, W) |
Tightening torque | 0.8…1 N.m |
Insulation of Schneider ATV310A inverter | Electrical between power and control |
supply of Schneider ATV310A inverter | Internal supply for reference potentiometer: 5 V (4.75…5.25 V)DC, <10 mA with overload and short-circuit protection Internal supply for logic inputs: 24 V (20.4…28.8 V)DC, <100 mA with overload and short-circuit protection |
Analogue input number | 1 |
analogue input type | Configurable current AI1 0…20 mA 250 Ohm Configurable voltage AI1 0…10 V 30 kOhm Configurable voltage AI1 0…5 V 30 kOhm |
Discrete input number | 4 |
discrete input type | Programmable LI1…LI4 24 V 18…30 V |
discrete input logic | Negative logic (sink), > 16 V (state 0), < 10 V (state 1), input impedance 3.5 kOhm Positive logic (source), 0…< 5 V (state 0), > 11 V (state 1) |
sampling duration | 10 ms for analogue input 20 ms, tolerance +/- 1 ms for logic input |
linearity error of Schneider ATV310A inverter | +/- 0.3 % of maximum value for analogue input |
Analogue output number | 1 |
analogue output type | AO1 software-configurable voltage: 0…10 V, impedance: 470 Ohm, resolution 8 bits AO1 software-configurable current: 0…20 mA, impedance: 800 Ohm, resolution 8 bits |
Discrete output number | 2 |
discrete output type | Logic output LO+, LO- Protected relay output R1A, R1B, R1C 1 C/O |
minimum switching current | 5 mA at 24 V DC for logic relay |
maximum switching current | 2 A at 250 V AC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay 2 A at 30 V DC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay 3 A at 250 V AC on resistive load cos phi = 1 L/R = 0 ms for logic relay 4 A at 30 V DC on resistive load cos phi = 1 L/R = 0 ms for logic relay |
Acceleration and deceleration ramps | U Linear from 0…999.9 s S |
braking to standstill | By DC injection, <30 s |
protection type of Schneider ATV310A inverter | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
frequency resolution | Analog input: converter A/D, 10 bits Display unit: 0.1 Hz |
time constant of Schneider ATV310A inverter | 20 ms +/- 1 ms for reference change |
Operating position | Vertical +/- 10 degree |
Height of Schneider ATV310A inverter | 143 mm |
Width of Schneider ATV310A inverter | 72 mm |
Depth of Schneider ATV310A inverter | 140 mm |
Product weight of Schneider ATV310A inverter | 0.8 kg |
electromagnetic compatibility | Electrical fast transient/burst immunity test – test level: level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test – test level: level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances – test level: level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test – test level: level 3 conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11 Surge immunity test – test level: level 3 conforming to EN/IEC 61000-4-5 |
Standards of Schneider ATV310A inverter | EN/IEC 61800-3 EN/IEC 61800-5-1 |
IP degree of protection | IP20 without blanking plate on upper part IP41 top |
pollution degree of Schneider ATV310A inverter | 2 conforming to EN/IEC 61800-5-1 |
environmental characteristic | Dust pollution resistance class 3S2 conforming to EN/IEC 60721-3-3 Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 |
shock resistance of Schneider ATV310A inverter | 15 gn conforming to EN/IEC 60068-2-27 for 11 ms |
relative humidity of Schneider ATV310A inverter | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Ambient air temperature for storage | -25…70 °C |
ambient air temperature for operation | -10…55 °C without derating 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C |
operating altitude | <= 1000 m without derating |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”