Schneider phase sequence lack of phase undervoltage protector RM22TU23 multi-function three-phase phase Xu control relay
- Name: Schneider phase sequence lack of phase undervoltage protector RM22TU23 multi-function three-phase phase Xu control relay
- Brand: Schneider
- Model: RM22TU23
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER phase sequence lack of phase undervoltage protector RM22TU23 multi-function three-phase phase Xu control relay
Product Series | Harmony Control Relays |
---|---|
product type | 3-phase control relay |
relay type | Control relay |
Number of grid phases | Phase 3 |
Relay name | RM22TR |
Relay Monitoring Parameters | Undervoltage Monitoring Phase Sequence Phase Failure Monitoring |
delay type of Schneider phase sequence | None |
Switching capacity in VA | 2000VA |
Measuring range | 380…480 V voltage AC |
contact type | 2 OC |
reset time | 1500 ms at maximum voltage |
Maximum Switching Voltage | 250V AC |
Minimum switching current [Imin] | 10 mA at 5 V DC |
Maximum switching current | 8A AC |
Rated supply voltage [Us] | 380…480 V AC |
Power supply voltage range | 304…576 V AC |
operating limits | – 20 % + 20 % Un |
Power consumption VA | 15 VA at 480 V AC 60 Hz |
Voltage Monitoring Threshold | < 100 V AC |
supply voltage frequency | 50…60 Hz +/- 10 % |
output contact | 2 C/O |
set precision | +/- 10 % of full scale |
switching threshold error | <= 0.05 % per degree Celsius based on permissible ambient air temperature <= 1 % within supply voltage range |
Latency Accuracy Settings | 10P |
delay error | <= 0.05 % per degree Celsius based on permissible ambient air temperature <= 1 % within supply voltage range |
hysteresis of Schneider phase sequence | 2 % fixed optional |
Rising delay at power-up | 650ms |
maximum measuring cycle | 150 ms period measured in true rms value |
Threshold adjustment voltage | 2…20 % selected Un |
voltage range | 380…480 VPP |
Repeatability | +/- 0.5 % for input and measurement circuits |
Measurement error | < 1 % over the entire range with a voltage change < 0.05 %/°C with a temperature change |
Response time | <= 300ms |
Type of overvoltage | III according to IEC 60664-1 III according to UL 508 |
Insulation resistance | > 100 MΩ at 500 V DC conforming to IEC 60255-27 |
installation location | Any position |
Wiring capacity | Screw terminal, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) Solid without wire terminal Screw terminal, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16 ) flexible wire with wire terminal screw terminal, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) rigid wire without wire terminal screw terminal, 1 x 0.2…1 x 2.5 mm² ( AWG 24…AWG 14) flexible wire with wire terminal |
Tightening torque | 0.6…1 Nm conforming to IEC 60947-1 |
covering material | Flame retardant plastic |
LED status of Schneider phase sequence | LED (yellow) relay ON LED (green) energized |
installation method | 35 mm DIN rail conforming to EN/IEC 60715 |
Electrical life | 100000 times |
Mechanical life | 10000000 times |
use category | AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
Safe and reliable data | MTTFd = 388.1 years B10d = 350000 |
contact material | Cadmium free |
width of Schneider phase sequence | 22.5 mm |
Product Weight | 0.09 kg |
Anti-instantaneous power failure | 10ms |
electromagnetic compatibility | Exemption for use in residential, commercial and light-industrial environments Transmission standards per EN/IEC 61000-6-1 Exemption for industrial environments per EN/IEC 61000-6-2 Transmission standards for residential, commercial and light- industrial environments per EN/IEC 61000- 6-3 Transmission standards for industrial environments in accordance with EN/IEC 61000-6-4 Anti-static interference – test level: 6 kV (contact discharge) Level 3 in accordance with IEC 61000-4-2 Anti-static interference – test level: 8 kV (air Discharge) Class 3 Complies with IEC 61000-4-2 Radio Frequency Electromagnetic Field Radiation Immunity Test – Test Level: 10 V/m3 Class Complies with IEC 61000-4-3 Immunity to Fast Transients – Test Level: 4 kV (Direct Connection) Class 4 Complies with IEC 61000-4-4 Immunity to fast transients – Test level: 2 kV (capacitive coupling) level 4 Complies with IEC 61000-4-4 Surge discharge immunity – Test level: 4 kV (Common mode) level 4 Conforms to IEC 61000 -4-5 Surge Discharge Immunity- Test Level: 2 kV (Differential Mode) Level 4 Conforms to IEC 61000-4-5 Conducted and Radiated Emissions Group B 1 Conforms to CISPR 11 Conducted and Radiated Emissions Class B Conforms to CISPR 22 |
Standards compliant | EN/IEC 60255-1 |
certified product | CSA RCM UL GL CE CCC EAC |
storage environment temperature | -40…70°C |
ambient temperature | -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC |
Relative humidity | 93…97 % at 25…55 °C conforming to IEC 60068-2-30 |
Anti-vibration | 0.075 mm (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) non-operating according to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) during operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) conforming to IEC 60068-2-6 during operation |
impact resistance | 15 gn (duration = 11 ms) for non-operating according to IEC 60068-2-27 5 gn (duration = 11 ms) for operating according to IEC 60068-2-27 |
IP protection class | IP20 according to IEC 60529 (screw terminals) IP40 according to IEC 60529 (housing) IP50 according to IEC 60529 (front panel) |
pollution level | 3 according to IEC 60664-1 3 according to UL 508 |
Dielectric test winding and winding, winding voltage to ground | 2.5 kV AC 50 Hz, 1 minute conforming to IEC 60255-27 |
Warranty of Schneider phase sequence | 18 months |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”