Schneider Schneider EasyPact TVS AC CONTACTOR LC1N3210M5N AC220V
- Name: Schneider Schneider EasyPact TVS AC CONTACTOR LC1N3210M5N AC220V
- Brand: Schneider
- Model: LC1N3210M5N
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER Schneider Schneider EasyPact TVS AC CONTACTOR LC1N3210M5N AC220V
Product Series | Compact |
---|---|
product type | Contactor |
product short name | LC1N |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-1 AC-3 AC-4 |
number of poles | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 50/60 Hz |
Rated operating current [Ie] | 32 A 60 °C) at <= 440 V AC AC-3 for power circuit 40 A 60 °C) at <= 440 V AC AC-1 for power circuit 14 A 60 °C) at< = 440 V AC AC-4 for power circuits |
[Uc] control circuit voltage | 230V AC 50Hz |
Motor power (kW) | 7.5 kW at 220/230 V AC 50/60 Hz 15 kW at 380/400 V AC 50/60 Hz 15 kW at 415/440 V AC 50/60 Hz 18.5 kW at 500 V AC 50/60 Hz 18.5 kW at 660/690 V AC 50/60 Hz |
Loop contact type | 3 NO |
Conventional thermal current [Ith] | 40 A at <60 °C for power circuits |
Rated making capacity [Irms] | 320 A at 440 V AC for power circuits according to IEC 60947-4-1 140 A AC for auxiliary contacts according to IEC 60947-5-1 |
Rated breaking capacity | 256 A at 440 V for power circuits conforming to IEC 60947 |
Rated short-time withstand current [Icw] | 260 A for power circuits at <40 °C – 10 s 138 A for power circuits at <40 °C – 60 s 60 A for power circuits at <40 °C – 600 s |
Fuses for use with relays | 10 A gG at <= 690 V for type 1 suitable control circuits conforming to IEC 60947-5-1 63 A gG at <= 690 V for type 1 suitable power circuits |
average impedance | 2.5 mΩ – Ith 50 A 50 Hz for power circuits |
power consumption per pole | 2W AC-3 5W AC-1 |
Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
pollution level | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV coil not connected to power circuit conforming to IEC 60947 |
Mechanical life | 8000000 times |
Electrical life | 1,000,000 AC-3 350,000 AC-1 200,000 AC-4 |
Control loop characteristics | AC at 50 Hz |
Control voltage limit | 0.85…1.1 Uc 55 °C run 50 Hz 0.3…0.6 Uc 55 °C release 50 Hz |
(~50Hz pickup) power consumption (VA) | 95 VA 50 Hz (0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 8.3 VA 50 Hz (0.3 20 °C) |
heat dissipation | 2…3 W for control circuits |
action time | 12…22 ms off 4…19 ms on opening |
operating frequency | 1800 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal control circuit: screw cable option1 1…4 mm² cable option : Solid wire without wire terminal Control circuit: Bolt fastening2 1…4 mm² Cable selection: Solid wire without wire terminal Power circuit: Bolt fastening1 1.5…6 mm² Cable selection: Hard wire without wire wire Wire terminal power circuit: screw-on2 1.5…6 mm² Cable option: rigid without wire terminal Power circuit: screw-on1 1…6 mm² cable option: flexible with cable terminal Power circuit: screw- on Solid 2 1…4 mm² Cable selection: Flexible with cable terminals |
Tightening torque | Control circuit: 1.2 Nm Power circuit: 2.1 Nm |
Auxiliary contact type | 1 NO |
Minimum switching voltage | 17 V for control circuits |
Minimum switching current [Imin] | 5 mA for control loop |
Insulation resistance | > 10 MΩ for control loops |
non-overlapping time | 1.5 ms power-on to ensure NC and NO contact 1.5 ms power-off to ensure NC and NO contact |
installation method | Chassis mounting DIN rail mounting |
standard | GB 14048.4 EN 60947-1 IEC 60947-1 EN 60947-4-1 IEC 60947-4-1 |
certified product | CCC |
IP protection class | IP20 conforming to IEC 60529 |
Protective measures | TH (pollution degree 3) conforming to IEC 60068 |
ambient air temperature | -20…70 °C (allowed at Uc) -60…80 °C storage -5…55 °C operation |
working altitude | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 |
Shock and vibration resistance | Shock resistance with contacts open (1.5 gn (5…300 Hz)) shock resistance with contacts closed (3 gn (5…300 Hz)) shock resistance with contacts closed (10 gn (11ms)) Shock performance Contact opening (6 gn (11ms)) |
high of Schneider Schneider EasyPact | 84 mm |
width of Schneider Schneider EasyPact | 56 mm |
depth of Schneider Schneider EasyPact | 86 mm |
Product Weight of Schneider Schneider EasyPact | 0.45 kg |
Warranty of Schneider Schneider EasyPact | 18 months |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”