Schneider time relay RE17RCMU

Schneider time relay RE17RCMU

Share to:

Aditional Informations

PRODUCT INFORMATION OF SCHNEIDER Schneider time relay RE17RCMU

 

Main

Range of product Harmony Timer Relays
Product or component type Single function relay
Discrete output type Relay
Width 17.5 mm
Device short name RE17R
Time delay type Off-delay
Time delay range 6…60 s
1…10 h
1…10 min
6…60 min
0.1…1 s
1…10 s
10…100 h
Nominal output current 8 A
Contacts type and composition 1 C/O
Contacts material Cadmium free
Height 90 mm
Depth 72 mm
control type Selector switch front panel
[Us] rated supply voltage 24…240 V AC 50/60 Hz
24 V DC
Voltage range 0.85…1.1 Us
supply frequency 50…60 Hz +/- 5 %
release of input voltage 10 V
connections – terminals Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end
tightening torque 0.6…1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing
repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
control signal pulse width 100 ms with load in parallel typical
30 ms typical
insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
reset time 120 ms on de-energisation typical
On-load factor 100 %
power consumption in VA 0…32 VA at 240 V AC
maximum power consumption in W 0.6 W at 24 V DC
minimum switching current 10 mA at 5 V DC
maximum switching current 8 A AC/DC
maximum switching voltage 250 V AC
Breaking capacity 2000 VA
operating frequency 10 Hz
electrical durability 100000 cycles (8 A at 250 V AC maximum) for resistive load
Mechanical durability 10000000 cycles
dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
power on delay 100 ms
Marking of Schneider time relay RE17RCMU CE
creepage distance 4 kV/3 conforming to IEC 60664-1
Safety reliability data B10d = 270000
MTTFd = 296.8 years
mounting position Any position in relation to normal vertical mounting plane
mounting support 35 mm DIN rail conforming to EN/IEC 60715
local signalling of Schneider time relay RE17RCMU LED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
Product weight of Schneider time relay RE17RCMU 0.07 kg
Time delay type of Schneider time relay RE17RCMU C
Functionality of Schneider time relay RE17RCMU Off-delay timing
Compatibility code RE17
Immunity to microbreaks 20 ms
Standards of Schneider time relay RE17RCMU EN 61000-6-4
EN 61000-6-2
EN 61000-6-3
2004/108/EC
2006/95/EC
IEC 61812-1
EN 61000-6-1
Product certifications CULus
GL
CSA
Ambient air temperature for storage -30…60 °C
Ambient air temperature for operation -20…60 °C
IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
vibration resistance of Schneider time relay RE17RCMU 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
shock resistance of Schneider time relay RE17RCMU 15 gn for 11 ms conforming to IEC 60068-2-27
relative humidity of Schneider time relay RE17RCMU 93 % without condensation conforming to IEC 60068-2-30
electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15…80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us