Product Series Compact
product type Contactor
product short name LC1N
Application field of contactor Applied to non-inductive or micro-inductive loads, and resistance furnaces
to AC loads with a power factor greater than or equal to 0.95
use category AC-4
AC-1
AC-3
number of poles 3P
Rated working voltage [Ue] Power circuit: <= 690 V AC 50/60 Hz
Rated operating current [Ie] 95 A 60 °C) at <= 440 V AC AC-3 for power circuit
110 A 60 °C) at <= 440 V AC AC-1 for power circuit
44 A 60 °C) at< = 440 V AC AC-4 for power circuits
[Uc] control circuit voltage 230V AC 50Hz
Motor power (kW) 45 kW at 660/690 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
25 kW at 220/230 V AC 50/60 Hz
45 kW at 380/400 V AC 50/60 Hz
45 kW at 415/440 V AC 50/60 Hz
Loop contact type 3 NO
Conventional thermal current [Ith] 110 A at <60 °C for power circuits
Rated making capacity [Irms] 950 A at 440 V AC for power circuits according to IEC 60947-4-1
140 A AC for auxiliary contacts according to IEC 60947-5-1
Rated breaking capacity 760 A at 440 V for power circuits conforming to IEC 60947
Rated short-time withstand current [Icw] 135 A for power circuits at <40 °C – 600 s
800 A for power circuits at <40 °C – 10 s
400 A for power circuits at <40 °C – 60 s
Fuses for use with relays 10 A gG at <= 690 V for type 1 suitable control circuits conforming to IEC 60947-5-1
160 A gG at <= 690 V for type 1 suitable power circuits
average impedance 0.8 mΩ – Ith 120 A 50 Hz for power circuits
power consumption per pole 7.2W AC-3
12W AC-1
Rated insulation voltage [Ui] 690 V conforming to IEC 60947-4-1
Overvoltage category III
pollution level 3
Rated impulse withstand voltage [Uimp] 6 kV coil not connected to power circuit conforming to IEC 60947
Mechanical life 300000 times
Electrical life 350,000 AC-1
900,000 AC-3
150,000 AC-4
Control loop characteristics AC at 50 Hz
Control voltage limit 0.85…1.1 Uc 55 °C run 50 Hz
0.3…0.6 Uc 55 °C release 50 Hz
(~50Hz pickup) power consumption (VA) 200VA 50Hz (0.75 20°C)
(~50Hz hold) power consumption (VA) 20VA 50Hz 0.3 20°C)
heat dissipation 6…10 W for control circuits
action time 20…35 ms off
6…30 ms on opening
operating frequency 1200 cycles/h at <60 °C
Wiring capacity Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals
Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal
Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals
control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal
control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals
Control circuit: Bolt tight1 1…2.5 mm² Cable selection: Flexible wire with wire terminals
Power circuit: Bolt fastened1 4…50 mm² Cable selection: Flexible wire with wire Terminals
Power circuit: screw-on2 4…16 mm² Cable option: flexible with wire terminal
Power circuit: screw-on1 4…50 mm² Cable option: solid without cable terminal
Power circuit: screw- on 2 4…25 mm² Cable option: solid without cable terminals
Tightening torque Control circuit: 1.2 Nm
Power circuit: 12 Nm
Auxiliary contact type 1 NO + 1 NC
Minimum switching voltage 17 V for control circuits
Minimum switching current [Imin] 5 mA for control loop
Insulation resistance > 10 MΩ for control loops
non-overlapping time 1.5 ms power-on to ensure NC and NO contact
1.5 ms power-off to ensure NC and NO contact
installation method Chassis mounting
DIN rail mounting
standard IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
GB 14048.4
EN 60947-1
certified product CCC
IP protection class IP20 conforming to IEC 60529
Protective measures TH (pollution degree 3) conforming to IEC 60068
ambient air temperature -20…70 °C (allowed at Uc)
-60…80 °C storage
-5…55 °C operation
working altitude 3000 m None
Fire resistance and abnormal high temperature resistance 850 °C conforming to IEC 60695-2-1
Shock and vibration resistance Shock resistance with contacts open (1.5 gn (5…300 Hz))
shock resistance with contacts closed (3 gn (5…300 Hz))
shock resistance with contacts open (6 gn (11ms))
shock resistance Performance Contact closed state (7 gn (11ms))
high of Spot Schneider AC contactor LC1N95M5N 127mm
width of Spot Schneider AC contactor LC1N95M5N 85 mm
depth of Spot Schneider AC contactor LC1N95M5N 121mm
Product Weight 1.52kg
Warranty of Spot Schneider AC contactor LC1N95M5N 18 months

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us