TM221C40R plc program controller, M221 series PLC programmable controller spot
- Name: TM221C40R plc program controller, M221 series PLC programmable controller spot
- Brand: Schneider
- Model: TM221C40R
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER TM221C40R plc program controller, M221 series PLC programmable controller spot
Range of product | Modicon M221 |
---|---|
Product or component type | Logic controller |
[Us] rated supply voltage | 100…240 V AC |
discrete input number | 24, discrete input conforming to IEC 61131-2 Type 1 |
analogue input number of TM221C40R plc program controller | 2 at 0…10 V |
Discrete output type of TM221C40R plc program controller | Relay normally open |
discrete output number | 16 relay |
discrete output voltage | 5…125 V DC 5…250 V AC |
discrete output current | 2 A |
Discrete I/O number | 40 |
maximum number of I/O expansion module | 7 for relay output |
Supply voltage limits | 85…264 V |
Network frequency | 50/60 Hz |
Inrush current | 40 A |
maximum power consumption in VA | 67 VA at 100…240 V with max number of I/O expansion module 37 VA at 100…240 V without I/O expansion module |
power supply output current | 0.52 A 5 V for expansion bus 0.24 A 24 V for expansion bus |
discrete input logic | Sink or source (positive/negative) |
Discrete input voltage | 24 V |
Discrete input voltage type | DC |
Analogue input resolution | 10 bits |
LSB value of TM221C40R plc program controller | 10 mV |
conversion time | 1 ms per channel + 1 controller cycle time for analogue input analog input |
permitted overload on inputs | +/- 30 V DC for 5 min (maximum) for analog input +/- 13 V DC (permanent) for analog input |
voltage state 1 guaranteed | >= 15 V for input |
voltage state 0 guaranteed | <= 5 V for input |
discrete input current | 7 mA for discrete input 5 mA for fast input |
input impedance | 3.4 kOhm for discrete input 100 kOhm for analog input 4.9 kOhm for fast input |
response time of TM221C40R plc program controller | 35 µs turn-off, I2…I5 terminal(s) for input 10 ms turn-on for output 10 ms turn-off for output 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input |
configurable filtering time | 0 ms for input 3 ms for input 12 ms for input |
output voltage limits | 125 V DC 277 V AC |
maximum current per output common | 7 A |
absolute accuracy error | +/- 1 % of full scale for analog input |
electrical durability | 100000 cycles AC-12, 120 V, 240 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive 300000 cycles AC-12, 120 V, 80 VA, resistive 300000 cycles AC-12, 240 V, 160 VA, resistive 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive 100000 cycles DC-12, 24 V, 48 W, resistive 300000 cycles DC-12, 24 V, 16 W, resistive 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) |
switching frequency | 20 switching operations/minute with maximum load |
mechanical durability | 20000000 cycles for relay output |
minimum load | 1 mA at 5 V DC for relay output |
protection type | Without protection at 5 A |
reset time of TM221C40R plc program controller | 1 s |
memory capacity | 256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM |
data backed up of TM221C40R plc program controller | 256 kB built-in flash memory for backup of application and data |
data storage equipment | 2 GB SD card (optional) |
battery type | BR2032 lithium non-rechargeable, battery life: 4 year(s) |
backup time | 1 year at 25 °C (by interruption of power supply) |
execution time for 1 KInstruction | 0.3 ms for event and periodic task |
execution time per instruction | 0.2 µs Boolean |
exct time for event task | 60 µs response time |
Maximum size of object areas | 512 %M memory bits 512 %KW constant words 8000 %MW memory words 255 %C counters 255 %TM timers |
Realtime clock | With |
clock drift of TM221C40R plc program controller | <= 30 s/month at 25 °C |
regulation loop | Adjustable PID regulator up to 14 simultaneous loops |
counting input number | 4 fast input (HSC mode) at 100 kHz 32 bits |
counter function | Single phase Pulse/direction A/B |
integrated connection type | USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with RJ45 connector and RS485 interface Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface |
supply of TM221C40R plc program controller | (Serial)serial link supply: 5 V, <200 mA |
transmission rate | 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for USB |
communication port protocol | USB port: USB – SoMachine-Network Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network |
local signalling of TM221C40R plc program controller | 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED per channel (green) for I/O state |
electrical connection | Removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal |
maximum cable distance between devices | Shielded cable: <10 m for fast input Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input |
insulation of TM221C40R plc program controller | Between input and internal logic at 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs Between supply and ground at 1500 V AC Between sensor power supply and ground at 500 V AC Between input and ground at 500 V AC Between output and ground at 1500 V AC Between supply and internal logic at 2300 V AC Between sensor power supply and internal logic at 500 V AC Between output and internal logic at 2300 V AC Between Ethernet terminal and internal logic at 500 V AC Between supply and sensor power supply at 2300 V AC |
Marking of TM221C40R plc program controller | CE |
sensor power supply | 24 V DC at 250 mA supplied by the controller |
mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
Height of TM221C40R plc program controller | 90 mm |
Depth of TM221C40R plc program controller | 70 mm |
Width of TM221C40R plc program controller | 160 mm |
Product weight of TM221C40R plc program controller | 0.456 kg |
Standards of TM221C40R plc program controller | EN/IEC 61131-2 EN/IEC 60664-1 EN/IEC 61010-2-201 |
Product certifications | RCM IACS E10 LR CSA cULus DNV-GL ABS EAC |
Environmental characteristic | Ordinary and hazardous location |
resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2 4 kV on contact conforming to EN/IEC 61000-4-2 |
resistance to electromagnetic fields | 10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3 |
resistance to magnetic fields | 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 |
resistance to fast transients | 2 kV (power lines) conforming to EN/IEC 61000-4-4 2 kV (relay output) conforming to EN/IEC 61000-4-4 1 kV (I/O) conforming to EN/IEC 61000-4-4 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4 |
surge withstand of TM221C40R plc program controller | 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5 2 kV relay output common mode conforming to EN/IEC 61000-4-5 1 kV I/O common mode conforming to EN/IEC 61000-4-5 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5 1 kV relay output differential mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 |
resistance to conducted disturbances | 10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6 3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
electromagnetic emission | Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011 Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011 Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011 Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011 |
Immunity to microbreaks | 10 ms |
ambient air temperature for operation | -10…55 °C (horizontal installation) -10…35 °C (vertical installation) |
Ambient air temperature for storage | -25…70 °C |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”