Main

Range of product Modicon M221
Product or component type Logic controller
[Us] rated supply voltage 100…240 V AC
discrete input number 24, discrete input conforming to IEC 61131-2 Type 1
analogue input number of TM221C40R plc program controller 2 at 0…10 V
Discrete output type of TM221C40R plc program controller Relay normally open
discrete output number 16 relay
discrete output voltage 5…125 V DC
5…250 V AC
discrete output current 2 A
Discrete I/O number 40
maximum number of I/O expansion module 7 for relay output
Supply voltage limits 85…264 V
Network frequency 50/60 Hz
Inrush current 40 A
maximum power consumption in VA 67 VA at 100…240 V with max number of I/O expansion module
37 VA at 100…240 V without I/O expansion module
power supply output current 0.52 A 5 V for expansion bus
0.24 A 24 V for expansion bus
discrete input logic Sink or source (positive/negative)
Discrete input voltage 24 V
Discrete input voltage type DC
Analogue input resolution 10 bits
LSB value of TM221C40R plc program controller 10 mV
conversion time 1 ms per channel + 1 controller cycle time for analogue input analog input
permitted overload on inputs +/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
voltage state 1 guaranteed >= 15 V for input
voltage state 0 guaranteed <= 5 V for input
discrete input current 7 mA for discrete input
5 mA for fast input
input impedance 3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
response time of TM221C40R plc program controller 35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
configurable filtering time 0 ms for input
3 ms for input
12 ms for input
output voltage limits 125 V DC
277 V AC
maximum current per output common 7 A
absolute accuracy error +/- 1 % of full scale for analog input
electrical durability 100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
switching frequency 20 switching operations/minute with maximum load
mechanical durability 20000000 cycles for relay output
minimum load 1 mA at 5 V DC for relay output
protection type Without protection at 5 A
reset time of TM221C40R plc program controller 1 s
memory capacity 256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
data backed up of TM221C40R plc program controller 256 kB built-in flash memory for backup of application and data
data storage equipment 2 GB SD card (optional)
battery type BR2032 lithium non-rechargeable, battery life: 4 year(s)
backup time 1 year at 25 °C (by interruption of power supply)
execution time for 1 KInstruction 0.3 ms for event and periodic task
execution time per instruction 0.2 µs Boolean
exct time for event task 60 µs response time
Maximum size of object areas 512 %M memory bits
512 %KW constant words
8000 %MW memory words
255 %C counters
255 %TM timers
Realtime clock With
clock drift of TM221C40R plc program controller <= 30 s/month at 25 °C
regulation loop Adjustable PID regulator up to 14 simultaneous loops
counting input number 4 fast input (HSC mode) at 100 kHz 32 bits
counter function Single phase
Pulse/direction
A/B
integrated connection type USB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
supply of TM221C40R plc program controller (Serial)serial link supply: 5 V, <200 mA
transmission rate 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
communication port protocol USB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
local signalling of TM221C40R plc program controller 1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
electrical connection Removable screw terminal block for inputs
removable screw terminal block for outputs
terminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
maximum cable distance between devices Shielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
insulation of TM221C40R plc program controller Between input and internal logic at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
Between supply and ground at 1500 V AC
Between sensor power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
Marking of TM221C40R plc program controller CE
sensor power supply 24 V DC at 250 mA supplied by the controller
mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height of TM221C40R plc program controller 90 mm
Depth of TM221C40R plc program controller 70 mm
Width of TM221C40R plc program controller 160 mm
Product weight of TM221C40R plc program controller 0.456 kg
Standards of TM221C40R plc program controller EN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61010-2-201
Product certifications RCM
IACS E10
LR
CSA
cULus
DNV-GL
ABS
EAC
Environmental characteristic Ordinary and hazardous location
resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields 10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
surge withstand of TM221C40R plc program controller 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
resistance to conducted disturbances 10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Immunity to microbreaks 10 ms
ambient air temperature for operation -10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage -25…70 °C

FAQ ( frequently ask questions )

A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts

A: By sea to your nearest port

By air to your nearest airport

By express (DHL,UPS,FEDEX,TNT,EMS)to your door

When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods

A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.

DHLAround 3-5 working days
FedExAround 3-5 working days
UPS/TNTAround 6-8 working days
EMSAround 10-15 working days
AIRAround 5-7 working days
SEAAround 15-30 working days

A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost

A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products

A: You can send it back to repair ,but the freight and repair charge will be paid by you.

A: TT, Western Union, Pay pal, You can choose a convinient way for you .

Kindly contact our staff to get more answers. Thanks for your cooperation!!!”

RElated Products

send your message to us