TM241CE40U plc program controller, M241 series PLC programmable controller spot
- Name: TM241CE40U plc program controller, M241 series PLC programmable controller spot
- Brand: Schneider
- Model: TM241CE40U
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER TM241CE40U plc program controller, M241 series PLC programmable controller spot
Range of product | Modicon M241 |
---|---|
Product or component type | Logic controller |
[Us] rated supply voltage | 24 V DC |
discrete input number | 24, discrete input 8 fast input conforming to IEC 61131-2 Type 1 |
Discrete output type | Transistor |
discrete output number | 16 transistor 4 fast output |
discrete output voltage | 24 V DC for transistor output |
discrete output current | 0.1 A for fast output (PTO mode) (Q0…Q3) 0.5 A for transistor output (Q0…Q15) |
Discrete I/O number | 40 |
maximum number of I/O expansion module | 7 (local I/O-Architecture) 14 (remote I/O-Architecture) |
Supply voltage limits | 20.4…28.8 V |
Inrush current | 50 A |
power consumption in W | 32.6…40.4 W (with max number of I/O expansion module) |
discrete input logic | Sink or source |
Discrete input voltage | 24 V |
Discrete input voltage type | DC |
voltage state 1 guaranteed | >= 15 V for input |
voltage state 0 guaranteed | <= 5 V for input |
discrete input current | 10.7 mA for fast input 7 mA for input |
input impedance | 4.7 kOhm for input 2.81 kOhm for fast input |
response time | <= 2 µs turn-on, I0…I7 terminal(s) for fast input <= 2 µs turn-off, I0…I7 terminal(s) for fast input <= 2 µs turn-on, Q0…Q3 terminal(s) for fast output <= 2 µs turn-off, Q0…Q3 terminal(s) for fast output 50 µs turn-on, I0…I15 terminal(s) for input 50 µs turn-off, I0…I15 terminal(s) for input <= 34 µs turn-on, Q0…Q15 terminal(s) for output <= 250 µs turn-off, Q0…Q15 terminal(s) for output |
configurable filtering time | 1 µs for fast input 12 ms for fast input 0 ms for input 1 ms for input 4 ms for input 12 ms for input |
Discrete output logic | Negative logic (sink) |
output voltage limits | 30 V DC |
maximum current per output common | 2 A |
maximum output frequency | 20 kHz for fast output (PWM mode) 100 kHz for fast output (PLS mode) 1 kHz for output |
accuracy | +/- 0.1 % at 0.02…0.1 kHz for fast output +/- 1 % at 0.1…1 kHz for fast output |
maximum leakage current | 5 µA for output |
maximum voltage drop | <1 V |
maximum tungsten load | <2.4 W |
protection type | Short-circuit protection Short-circuit and overload protection with automatic reset Reverse polarity protection for fast output |
reset time | 10 ms automatic reset output 12 s automatic reset fast output |
memory capacity | 8 MB for program 64 MB for system memory RAM |
data backed up | 128 MB built-in flash memory for backup of user programs |
data storage equipment | <= 16 GB SD card (optional) |
battery type | BR2032 lithium non-rechargeable, battery life: 4 year(s) |
backup time | 2 years at 25 °C |
execution time for 1 KInstruction | 0.3 ms for event and periodic task 0.7 ms for other instruction |
Application structure | 8 external event tasks 3 cyclic master tasks + 1 freewheeling task 4 cyclic master tasks 8 event tasks |
Realtime clock | With |
clock drift | <= 60 s/month at 25 °C |
positioning functions | PTO function 4 channel(s) (positioning frequency: 100 kHz) PTO function 4 channel(s) for transistor output (positioning frequency: 1 kHz) |
counting input number | 4 fast input (HSC mode) at 200 kHz 16 standard input at 1 kHz |
control signal type | A/B at 100 kHz for fast input (HSC mode) Pulse/direction at 200 kHz for fast input (HSC mode) Single phase at 200 kHz for fast input (HSC mode) |
integrated connection type | Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Non isolated serial link serial 2 with removable screw terminal block connector and RS485 interface USB port with mini B USB 2.0 connector Ethernet with RJ45 connector |
supply | (Serial 1)serial link supply: 5 V, <200 mA |
transmission rate | 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for bus length of 3 m for USB 10/100 Mbit/s for Ethernet |
communication port protocol | Non isolated serial link: Modbus master/slave |
port Ethernet | 10BASE-T/100BASE-TX – 1 port(s) copper cable |
ethernet services | FDR DHCP server via TM4 Ethernet switch network module DHCP client embedded Ethernet port SMS notifications Updating firmware SNMP client/server Programming NGVL Monitoring IEC VAR ACCESS FTP client/server Downloading SQL client Modbus TCP client I/O scanner Ethernet/IP originator I/O scanner embedded Ethernet port Ethernet/IP target, Modbus TCP server and Modbus TCP slave Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client |
local signalling | 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (red) for I/O error (I/O) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED (red) for bus fault on TM4 (TM4) 1 LED per channel (green) for I/O state 1 LED (green) for Ethernet port activity |
electrical connection | Removable screw terminal blockfor inputs and outputs (pitch 5.08 mm) removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm) |
maximum cable distance between devices | Unshielded cable: <50 m for input Shielded cable: <10 m for fast input Unshielded cable: <50 m for output Shielded cable: <3 m for fast output |
insulation | Between supply and internal logic at 500 V AC Non-insulated between supply and ground Between input and internal logic at 500 V AC Non-insulated between inputs Between fast input and internal logic at 500 V AC Between output and internal logic at 500 V AC Non-insulated between outputs Between fast output and internal logic at 500 V AC Between output groups at 500 V AC |
Marking | CE |
surge withstand | 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 1 kV relay output differential mode conforming to EN/IEC 61000-4-5 1 kV input common mode conforming to EN/IEC 61000-4-5 1 kV transistor output common mode conforming to EN/IEC 61000-4-5 |
Web services | Web server |
maximum number of connections | 8 Modbus server 8 SoMachine protocol 10 web server 4 FTP server 16 Ethernet/IP target 8 Modbus client |
number of slave | 64 Modbus TCP: 16 EtherNet/IP: |
cycle time | 10 ms 16 EtherNet/IP 64 ms 64 Modbus TCP |
mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
Height | 90 mm |
Depth | 95 mm |
Width | 190 mm |
Product weight | 0.62 kg |
standards | ANSI/ISA 12-12-01 CSA C22.2 No 142 CSA C22.2 No 213 EN/IEC 61131-2:2007 Marine specification (LR, ABS, DNV, GL) UL 1604 UL 508 |
Product certifications | CULus RCM CSA IACS E10 |
resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2 4 kV on contact conforming to EN/IEC 61000-4-2 |
resistance to electromagnetic fields | 10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz…3 GHz conforming to EN/IEC 61000-4-3 |
resistance to fast transients | 2 kV (power lines) conforming to EN/IEC 61000-4-4 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4 1 kV (input) conforming to EN/IEC 61000-4-4 1 kV (transistor output) conforming to EN/IEC 61000-4-4 |
resistance to conducted disturbances | 10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6 3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
electromagnetic emission | Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 Radiated emissions – test level: 40 dBμV/m QP class A at 30…230 MHz conforming to EN/IEC 55011 Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 Radiated emissions – test level: 47 dBμV/m QP class A at 230…1000 MHz conforming to EN/IEC 55011 |
Immunity to microbreaks | 10 ms |
ambient air temperature for operation | -10…50 °C (vertical installation) -10…55 °C (horizontal installation) |
Ambient air temperature for storage | -25…70 °C |
relative humidity | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
IP degree of protection | IP20 with protective cover in place |
Pollution degree | 2 |
Operating altitude | 0…2000 m |
Storage altitude | 0…3000 m |
vibration resistance | 3.5 mm at 5…8.4 Hz on symmetrical rail 3 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 3 gn at 8.4…150 Hz on panel mounting |
shock resistance | 15 gn for 11 ms |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”