PRODUCT INFORMATION OF SCHNEIDER TM251MESE plc program controller, M251 series PLC programmable controller spot
Range of product | Modicon M251 |
---|---|
Product or component type | Logic controller |
[Us] rated supply voltage | 24 V DC |
maximum number of I/O expansion module | 7 (local I/O-Architecture) 14 (remote I/O-Architecture) |
Supply voltage limits | 20.4…28.8 V |
Inrush current | 50 A |
power consumption in W | 32.6…40.4 W (with max number of I/O expansion module) |
memory capacity of TM251MESE plc program controller | 8 MB for program 64 MB for system memory RAM |
data backed up of TM251MESE plc program controller | 128 MB built-in flash memory for backup of user programs |
data storage equipment | <= 16 GB SD card (optional) |
battery type of TM251MESE plc program controller | BR2032 lithium non-rechargeable, battery life: 4 year(s) |
backup time | 2 years at 25 °C |
execution time for 1 KInstruction | 0.3 ms for event and periodic task 0.7 ms for other instruction |
Application structure | 4 cyclic master tasks 8 event tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks |
Realtime clock | With |
clock drift of TM251MESE plc program controller | <= 60 s/month at 25 °C |
integrated connection type | USB port with mini B USB 2.0 connector Non isolated serial link serial with RJ45 connector and RS232/RS485 interface Dual-port Ethernet 1 with RJ45 connector Ethernet port Ethernet 2 with RJ45 connector |
supply of TM251MESE plc program controller | (Serial)serial link supply: 5 V, <200 mA |
transmission rate | 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for bus length of 3 m for USB |
communication port protocol | USB port: USB – SoMachine-Network Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network |
port Ethernet | Ethernet 1 marking 10BASE-T/100BASE-TX – 2 copper cable Ethernet 2 marking 10BASE-T/100BASE-TX – 1 copper cable |
Web services | Web server |
communication service | Downloading IEC VAR ACCESS Modbus TCP client Modbus TCP server Modbus TCP slave device Monitoring NGVL Programming Updating firmware SMS notifications DHCP client (Eth1) DHCP server (Eth2) Ethernet/IP originator (Eth2) Ethernet/IP target (Eth1, Eth2) Ethernet/IP scanner (Eth2) Modbus TCP I/O Scanner and Messaging (Eth2) FDR FTP client/server SNMP client/server SQL client Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client |
maximum number of connections | 8 Modbus server 8 Modbus client 16 Ethernet/IP target 4 FTP server 10 web server 8 SoMachine protocol |
number of slave | 16 EtherNet/IP: 64 Modbus TCP: |
cycle time of TM251MESE plc program controller | 10 ms 16 EtherNet/IP 64 ms 64 Modbus TCP |
local signalling | 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (red) for I/O error (I/O) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL 1 LED (red) for bus fault on TM4 (TM4) 1 LED (green) for Ethernet activity (ETH1) 1 LED (green) for Ethernet activity (ETH2) |
electrical connection | Removable screw terminal blockpower supply (pitch 5.08 mm) |
insulation of TM251MESE plc program controller | Non-insulated between supply and internal logic Between supply and ground at 500 V AC |
Marking | CE |
surge withstand | 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 1 kV power lines common mode conforming to EN/IEC 61000-4-5 0.5 kV power lines differential mode conforming to EN/IEC 61000-4-5 |
mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
Height of TM251MESE plc program controller | 90 mm |
Depth of TM251MESE plc program controller | 95 mm |
Width of TM251MESE plc program controller | 54 mm |
Product weight | 0.22 kg |
standards of TM251MESE plc program controller | ANSI/ISA 12-12-01 CSA C22.2 No 142 CSA C22.2 No 213 EN/IEC 61131-2:2007 Marine specification (LR, ABS, DNV, GL) UL 1604 UL 508 |
Product certifications | CULus CSA |
resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2 4 kV on contact conforming to EN/IEC 61000-4-2 |
resistance to electromagnetic fields | 10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz…3 GHz conforming to EN/IEC 61000-4-3 |
resistance to fast transients | 2 kV (power lines) conforming to EN/IEC 61000-4-4 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4 |
resistance to conducted disturbances | 10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6 3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
electromagnetic emission | Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011 Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to EN/IEC 55011 |
Immunity to microbreaks | 10 ms |
ambient air temperature for operation | -10…35 °C (vertical installation) -10…55 °C (horizontal installation) |
Ambient air temperature for storage | -25…70 °C |
relative humidity | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
IP degree of protection | IP20 with protective cover in place |
Pollution degree | 2 |
Operating altitude | 0…2000 m |
Storage altitude | 0…3000 m |
vibration resistance | 3.5 mm at 5…8.4 Hz on symmetrical rail 3 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 3 gn at 8.4…150 Hz on panel mounting |
shock resistance of TM251MESE plc program controller | 15 gn for 11 ms |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”