TM3DM24R plc module, TM3 series PLC module spot
- Name: TM3DM24R plc module, TM3 series PLC module spot
- Brand: Schneider
- Model: TM3DM24R
- MOQ. : 1
- Warranty Time : 1 Year
- Certificates: ISO9001
- Price:
- Contact Person: Ms. Ma Meiying
- Email: sales@upalhd.com
- Email: sales.upalhd@hotmail.com
- Mobile-1: +86-16622133544
- Phone-2: +86-16602136043
Share to:
- Contact Peroson: Ms. Raihana
- Email: sales@upalhd.com
- Email: salse.upalhd@hotmail.com
- Phone-1: +86-16602136043
- Phone-2: +86-15557972300
Aditional Informations
PRODUCT INFORMATION OF SCHNEIDER TM3DM24R plc module, TM3 series PLC module spot
Range of product | Modicon TM3 |
---|---|
Product or component type | Discrete I/O module |
Range compatibility | Modicon M241 Modicon M251 Modicon M221 Modicon M262 |
discrete input number | 16 for input conforming to IEC 61131-2 Type 1 |
discrete input logic | Sink or source (positive/negative) |
Discrete input voltage | 24 V |
discrete input current | 7 mA for input |
Discrete output type | Relay normally open |
discrete output number | 8 |
Discrete output logic | Positive or negative |
discrete output voltage | 24 V DC for relay output 240 V AC for relay output |
discrete output current | 2000 mA for relay output |
Discrete I/O number | 24 |
current consumption | 5 mA at 5 V DC via bus connector (at state off) 0 mA at 24 V DC via bus connector (at state on) 0 mA at 24 V DC via bus connector (at state off) 65 mA at 5 V DC via bus connector (at state on) |
Discrete input voltage type | DC |
voltage state 1 guaranteed | 15…28.8 V for input |
current state 1 guaranteed | >= 2.5 mA (input) |
voltage state 0 guaranteed | 0…5 V for input |
current state 0 guaranteed | <= 1 mA (input) |
input impedance | 3.4 kOhm |
response time | 4 ms (turn-on) 4 ms (turn-off) |
Maximum current per output common | 7 A |
mechanical durability | 20000000 cycles |
minimum load | 10 mA at 5 V DC for relay output |
local signalling | 1 LED per channel (green) for I/O state |
electrical connection | 17 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs 11 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for outputs |
maximum cable distance between devices | Unshielded cable: <30 m for regular input |
insulation | Between input and internal logic at 500 V AC Non-insulated between inputs Between input groups and output groups at 1500 V AC Between open contact at 750 V AC Between output and internal logic at 500 V AC Non-insulated between outputs |
Marking of TM3DM24R plc module | CE |
mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
Height of TM3DM24R plc module | 90 mm |
Depth of TM3DM24R plc module | 84.6 mm |
Width of TM3DM24R plc module | 42.9 mm |
Standards of TM3DM24R plc module | EN/IEC 61131-2 EN/IEC 61010-2-201 |
Product certifications | CULus C-Tick |
resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2 4 kV on contact conforming to EN/IEC 61000-4-2 |
resistance to electromagnetic fields | 10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz…3 GHz conforming to EN/IEC 61000-4-3 |
resistance to magnetic fields | 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 |
resistance to fast transients | 1 kV for I/O conforming to EN/IEC 61000-4-4 2 kV for relay output conforming to EN/IEC 61000-4-4 |
surge withstand of TM3DM24R plc module | 2 kV output common mode conforming to EN/IEC 61000-4-5 1 kV input common mode conforming to EN/IEC 61000-4-5 |
resistance to conducted disturbances | 10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
electromagnetic emission | Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011 Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to EN/IEC 55011 |
ambient air temperature for operation | -10…35 °C vertical installation -10…55 °C horizontal installation |
Ambient air temperature for storage | -25…70 °C |
relative humidity of TM3DM24R plc module | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
IP degree of protection | IP20 with protective cover in place |
Pollution degree of TM3DM24R plc module | 2 |
Operating altitude of TM3DM24R plc module | 0…2000 m |
Storage altitude of TM3DM24R plc module | 0…3000 m |
vibration resistance | 3.5 mm at 5…8.4 Hz on DIN rail 3 gn at 8.4…150 Hz on DIN rail 3.5 mm at 5…8.4 Hz on panel 3 gn at 8.4…150 Hz on panel |
shock resistance of TM3DM24R plc module | 15 gn for 11 ms |
FAQ ( frequently ask questions )
A: inquiry→quotation→confirm→send PI→make the payment→arrange the parts→delivery→receive the parts
A: By sea to your nearest port
By air to your nearest airport
By express (DHL,UPS,FEDEX,TNT,EMS)to your door
When your order shipping out . we will provide you a tracking number. then you can know clearly the status of the goods
A: Motsly parts we have stock before you want to book with us pls email us and confirm the delivery time and price. Usually 1-5 working days.
DHL | Around 3-5 working days |
---|---|
FedEx | Around 3-5 working days |
UPS/TNT | Around 6-8 working days |
EMS | Around 10-15 working days |
AIR | Around 5-7 working days |
SEA | Around 15-30 working days |
A: Of course, common products are allowed to be exchanged as long as you pay the freight and custom cost
A: Yes, we have warranty for our parts. 3 months for PCB, 2 years for original roller and other roller, 3-5 years for COMI roller and 1 year for Yaskawa inverter. Please contact us to get more information for other products
A: You can send it back to repair ,but the freight and repair charge will be paid by you.
A: TT, Western Union, Pay pal, You can choose a convinient way for you .
Kindly contact our staff to get more answers. Thanks for your cooperation!!!”